PURPOSE: The surface chemical and physical properties of materials used for implants have a major influence on blood clot organization. This study aims to evaluate the blood clot extension (bce) on zirconia and titanium. bce was measured in association to surface roughness (Ra) and static contact angle (θ).MATERIALS AND METHODS: Forty disk-shaped samples of sandblasted yttria tetragonal zirconia polycrystal (sb-YTZP), machined titanium (m-Ti), and sandblasted, high-temperature, acid-etched titanium (p-Ti) were used in the present study. About 0.2 mL of human blood, immediately dropped onto the specimen's surface and left in contact for 5 minutes at room temperature, was used to measure the bce. Specimens were observed under confocal scanning laser and scanning electron microscopes.RESULTS: The bce (mean × 10(7)  ± standard deviation [SD] × 10(6)  μm(2) ) was 2.97 ± 6.68 for m-Ti, 5.64 ± 6.83 for p-Ti, and 3.61 ± 7.67 for sb-YTZP. p-Ti samples showed a significantly higher bce. Ra (mean ± SD [μm]) was 0.56 ± 0.7 for m-Ti, 3.78 ± 0.8 for p-Ti, and 2.68 ± 0.6 for sb-YTZP. The difference was not significant between sb-YTZP and p-Ti. θ (mean ± SD) was 55.6 ± 5.6 for m-Ti, 48.7 ± 2.8 for sb-YTZP, and 38.0 ± 2.2 for p-Ti. The difference was not significant between m-Ti and sb-YTZP.CONCLUSIONS: The sb-YTZP demonstrated a significantly lesser amount of bce compared with p-Ti specimens, notwithstanding that any significant difference was present between Ra and θ.

Fibrin Clot Extension on Zirconia Surface for Dental Implants: A Quantitative In Vitro Study.

GHERLONE, FELICE ENRICO;
2013-01-01

Abstract

PURPOSE: The surface chemical and physical properties of materials used for implants have a major influence on blood clot organization. This study aims to evaluate the blood clot extension (bce) on zirconia and titanium. bce was measured in association to surface roughness (Ra) and static contact angle (θ).MATERIALS AND METHODS: Forty disk-shaped samples of sandblasted yttria tetragonal zirconia polycrystal (sb-YTZP), machined titanium (m-Ti), and sandblasted, high-temperature, acid-etched titanium (p-Ti) were used in the present study. About 0.2 mL of human blood, immediately dropped onto the specimen's surface and left in contact for 5 minutes at room temperature, was used to measure the bce. Specimens were observed under confocal scanning laser and scanning electron microscopes.RESULTS: The bce (mean × 10(7)  ± standard deviation [SD] × 10(6)  μm(2) ) was 2.97 ± 6.68 for m-Ti, 5.64 ± 6.83 for p-Ti, and 3.61 ± 7.67 for sb-YTZP. p-Ti samples showed a significantly higher bce. Ra (mean ± SD [μm]) was 0.56 ± 0.7 for m-Ti, 3.78 ± 0.8 for p-Ti, and 2.68 ± 0.6 for sb-YTZP. The difference was not significant between sb-YTZP and p-Ti. θ (mean ± SD) was 55.6 ± 5.6 for m-Ti, 48.7 ± 2.8 for sb-YTZP, and 38.0 ± 2.2 for p-Ti. The difference was not significant between m-Ti and sb-YTZP.CONCLUSIONS: The sb-YTZP demonstrated a significantly lesser amount of bce compared with p-Ti specimens, notwithstanding that any significant difference was present between Ra and θ.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/10036
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact