Purpose The aim of this study was to test the feasibility and dosimetric accuracy of a method that employs planning CT-to-MVCT deformable image registration (DIR) for calculation of the daily dose for head and neck (HN) patients treated with Helical Tomotherapy (HT). Methods For each patient, the planning kVCT (CTplan) was deformably registered to the MVCT acquired at the 15th therapy session (MV15) with a B-Spline Free Form algorithm using Mattes mutual information (open-source software 3D Slicer), resulting in a deformed CT (CTdef). On the same day as MVCT15, a kVCT was acquired with the patient in the same treatment position (CT15). The original HT plans were recalculated both on CTdef and CT15, and the corresponding dose distributions were compared; local dose differences <2% of the prescribed dose (DD2%) and 2D/3D gamma-index values (2%-2 mm) were assessed respectively with Mapcheck SNC Patient software (Sun Nuclear) and with 3D-Slicer. Results On average, 87.9% ± 1.2% of voxels were found for DD2% (on average 27 slices available for each patient) and 94.6% ± 0.8% of points passed the 2D gamma analysis test while the 3D gamma test was satisfied in 94.8% ± 0.8% of body's voxels. Conclusions This study represents the first demonstration of the dosimetric accuracy of kVCT-to-MVCT DIR for dose of the day computations. The suggested method is sufficiently fast and reliable to be used for daily delivered dose evaluations in clinical strategies for adaptive Tomotherapy of HN cancer.

Validation of a method for “dose of the day” calculation in head-neck tomotherapy by using planning ct-to-MVCT deformable image registration / Branchini, M.; Fiorino, C.; Dell'Oca, I.; Belli, M. L.; Perna, L.; Di Muzio, N.; Calandrino, R.; Broggi, S.. - In: PHYSICA MEDICA. - ISSN 1120-1797. - 39:(2017), pp. 73-79. [10.1016/j.ejmp.2017.05.070]

Validation of a method for “dose of the day” calculation in head-neck tomotherapy by using planning ct-to-MVCT deformable image registration

Di Muzio N.;
2017-01-01

Abstract

Purpose The aim of this study was to test the feasibility and dosimetric accuracy of a method that employs planning CT-to-MVCT deformable image registration (DIR) for calculation of the daily dose for head and neck (HN) patients treated with Helical Tomotherapy (HT). Methods For each patient, the planning kVCT (CTplan) was deformably registered to the MVCT acquired at the 15th therapy session (MV15) with a B-Spline Free Form algorithm using Mattes mutual information (open-source software 3D Slicer), resulting in a deformed CT (CTdef). On the same day as MVCT15, a kVCT was acquired with the patient in the same treatment position (CT15). The original HT plans were recalculated both on CTdef and CT15, and the corresponding dose distributions were compared; local dose differences <2% of the prescribed dose (DD2%) and 2D/3D gamma-index values (2%-2 mm) were assessed respectively with Mapcheck SNC Patient software (Sun Nuclear) and with 3D-Slicer. Results On average, 87.9% ± 1.2% of voxels were found for DD2% (on average 27 slices available for each patient) and 94.6% ± 0.8% of points passed the 2D gamma analysis test while the 3D gamma test was satisfied in 94.8% ± 0.8% of body's voxels. Conclusions This study represents the first demonstration of the dosimetric accuracy of kVCT-to-MVCT DIR for dose of the day computations. The suggested method is sufficiently fast and reliable to be used for daily delivered dose evaluations in clinical strategies for adaptive Tomotherapy of HN cancer.
2017
CT-MVCT deformable registration
Dose of the day calculation
Head-neck adaptive
Algorithms
Head
Head and Neck Neoplasms
Humans
Neck
Radiometry
Software
Radiation Dosage
Radiotherapy Planning, Computer-Assisted
Radiotherapy, Intensity-Modulated
Tomography, X-Ray Computed
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/108143
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 17
social impact