Purpose: To implement knowledge-based (KB) automatic planning for helical TomoTherapy (HTT). The focus of the first clinical implementation was the case of high-risk prostate cancer, including pelvic node irradiation. Methods and Materials: One hundred two HTT clinical plans were selected to train a KB model using the RapidPlan tool incorporated in the Eclipse system (v13.6, Varian Inc). The individually optimized KB-based templates were converted into HTT-like templates and sent automatically to the HTT treatment planning system through scripting. The full dose calculation was set after 300 iterations without any additional planner intervention. Internal (20 patients in the training cohort) and external (28 new patients) validation were performed to assess the performance of the model: Automatic HTT plans (KB-TP) were compared against the original plans (TP) in terms of organs at risk and planning target volume (PTV) dose–volume parameters and by blinded clinical evaluation of 3 expert clinicians. Results: KB-TP plans were generally better than or equivalent to TP plans in both validation cohorts. A significant improvement in PTVs and rectum–PTV overlap dosimetry parameters were observed for both sets. Organ-at-risk sparing for KB-TP was slightly improved, which was more evident in the external validation group and for bladder and bowel. Clinical evaluation reported KB-TP to be better in 60% of cases and worse in 10% compared with TP (P < .05). Conclusions: The fully KB-based automatic planning workflow was successfully implemented for HTT planning optimization in the case of high-risk patients with prostate cancer.

Clinical Implementation of Knowledge-Based Automatic Plan Optimization for Helical Tomotherapy

Di Muzio N. G.;
2021-01-01

Abstract

Purpose: To implement knowledge-based (KB) automatic planning for helical TomoTherapy (HTT). The focus of the first clinical implementation was the case of high-risk prostate cancer, including pelvic node irradiation. Methods and Materials: One hundred two HTT clinical plans were selected to train a KB model using the RapidPlan tool incorporated in the Eclipse system (v13.6, Varian Inc). The individually optimized KB-based templates were converted into HTT-like templates and sent automatically to the HTT treatment planning system through scripting. The full dose calculation was set after 300 iterations without any additional planner intervention. Internal (20 patients in the training cohort) and external (28 new patients) validation were performed to assess the performance of the model: Automatic HTT plans (KB-TP) were compared against the original plans (TP) in terms of organs at risk and planning target volume (PTV) dose–volume parameters and by blinded clinical evaluation of 3 expert clinicians. Results: KB-TP plans were generally better than or equivalent to TP plans in both validation cohorts. A significant improvement in PTVs and rectum–PTV overlap dosimetry parameters were observed for both sets. Organ-at-risk sparing for KB-TP was slightly improved, which was more evident in the external validation group and for bladder and bowel. Clinical evaluation reported KB-TP to be better in 60% of cases and worse in 10% compared with TP (P < .05). Conclusions: The fully KB-based automatic planning workflow was successfully implemented for HTT planning optimization in the case of high-risk patients with prostate cancer.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/116596
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact