A study was conducted to evaluate the accuracy of GlucoDay (A. Menarini Diagnostics) during 48 h of continuous glucose monitoring (CGMS) in type 1 diabetic adolescents and use this novel approach to assess otherwise ignored nocturnal hypoglycaemias, in relationship to intermediate-acting insulin administration timing. Twenty type 1 diabetic adolescents with poor metabolic control were selected from our out-patient department. Equal doses of intermediate insulin were administered at 19:00 and at 22:00 of the first and second night of the study, respectively. Correlation coefficient between GlucoDay and standard glucometer was 0.94; 98.3% of data fall in the A + B area of Error Grid Analysis and 1.7% in the D area. The mean error was 13.9% overall and 16.4% with blood glucose values (BGV) < 75 mg/dl. The accuracy, +/- 15 mg/dl, was 82% for BGV < 75 mg/dl and 74% for BGV > 75 mg/dl. The CGMS discovered nocturnal hypoglycaemia (NH) in 12/18 patients, but no severe hypoglycaemia. During the first night, 8 asymptomatic NH episodes were found with BGV < 60 mg/dl and 12 with BGV < 80. During the second night, 4 asymptomatic NH episodes with BGV < 60 mg/dl and 5 with BGV < 80 were found. Furthermore, during the second night, the mean duration of BGV < 126 mg/dl was lower than in the first night. GlucoDay is a reliable device for CGMS in paediatric patients and able to determine asymptomatic NH. Bedtime insulin injections provided safer glycaemic profiles and a lower percentage of hypoglycaemic events, representing a safer insulin administration scheme.

Patients' evaluation of nocturnal hypoglycaemia with GlucoDay continuous glucose monitoring in paediatric patients / Meschi, F; Bonfanti, R; Rigamonti, A; Giulio, F; Battaglino, R; Viscardi, M; Poscia, A; Chiumello, G. - In: ACTA DIABETOLOGICA. - ISSN 0940-5429. - 47:4(2010), pp. 295-300. [10.1007/s00592-010-0181-9]

Patients' evaluation of nocturnal hypoglycaemia with GlucoDay continuous glucose monitoring in paediatric patients

Bonfanti R;
2010-01-01

Abstract

A study was conducted to evaluate the accuracy of GlucoDay (A. Menarini Diagnostics) during 48 h of continuous glucose monitoring (CGMS) in type 1 diabetic adolescents and use this novel approach to assess otherwise ignored nocturnal hypoglycaemias, in relationship to intermediate-acting insulin administration timing. Twenty type 1 diabetic adolescents with poor metabolic control were selected from our out-patient department. Equal doses of intermediate insulin were administered at 19:00 and at 22:00 of the first and second night of the study, respectively. Correlation coefficient between GlucoDay and standard glucometer was 0.94; 98.3% of data fall in the A + B area of Error Grid Analysis and 1.7% in the D area. The mean error was 13.9% overall and 16.4% with blood glucose values (BGV) < 75 mg/dl. The accuracy, +/- 15 mg/dl, was 82% for BGV < 75 mg/dl and 74% for BGV > 75 mg/dl. The CGMS discovered nocturnal hypoglycaemia (NH) in 12/18 patients, but no severe hypoglycaemia. During the first night, 8 asymptomatic NH episodes were found with BGV < 60 mg/dl and 12 with BGV < 80. During the second night, 4 asymptomatic NH episodes with BGV < 60 mg/dl and 5 with BGV < 80 were found. Furthermore, during the second night, the mean duration of BGV < 126 mg/dl was lower than in the first night. GlucoDay is a reliable device for CGMS in paediatric patients and able to determine asymptomatic NH. Bedtime insulin injections provided safer glycaemic profiles and a lower percentage of hypoglycaemic events, representing a safer insulin administration scheme.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/117202
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact