We evaluated the real-time diagnostic capability of a new tool enhancing early diagnosis of pump thrombosis (PT) of the HeartWare left ventricular assist device via time-frequency analysis (TFA) of the log files. We analyzed 173 log files, including 24 (14%) associated with a clinical diagnosis of PT and 149 (86%) controls. The 30-day log file records were discretized into consecutive windows of a 24-h duration, which were iteratively acquired and processed via TFA. This way, we simulated longitudinal acquisition of pump parameters and provided real-time analysis of consecutive data, thus resembling the clinical scenario. Sensitivity and specificity of the tool were 79% and 84%, respectively. Sensitivity against PT events with progressive “build-up” thrombus increased up to 95%, and early signs of a forthcoming PT were identified 10±8 days prior to its clinical manifestation. This study demonstrates high reliability and the potential for effective clinical translation of this prognostic tool.

Real-Time Analysis of the Log Files of the HeartWare Continuous-Flow Left Ventricular Assist Device for the Early Diagnosis of Pump Thrombosis: a Step Forward Toward Clinical Translation / Consolo, F.; Pappalardo, F.. - In: JOURNAL OF CARDIOVASCULAR TRANSLATIONAL RESEARCH. - ISSN 1937-5387. - 15:2(2022), pp. 408-415. [Epub ahead of print] [10.1007/s12265-021-10157-1]

Real-Time Analysis of the Log Files of the HeartWare Continuous-Flow Left Ventricular Assist Device for the Early Diagnosis of Pump Thrombosis: a Step Forward Toward Clinical Translation

Consolo F.
Primo
;
Pappalardo F.
Ultimo
2022-01-01

Abstract

We evaluated the real-time diagnostic capability of a new tool enhancing early diagnosis of pump thrombosis (PT) of the HeartWare left ventricular assist device via time-frequency analysis (TFA) of the log files. We analyzed 173 log files, including 24 (14%) associated with a clinical diagnosis of PT and 149 (86%) controls. The 30-day log file records were discretized into consecutive windows of a 24-h duration, which were iteratively acquired and processed via TFA. This way, we simulated longitudinal acquisition of pump parameters and provided real-time analysis of consecutive data, thus resembling the clinical scenario. Sensitivity and specificity of the tool were 79% and 84%, respectively. Sensitivity against PT events with progressive “build-up” thrombus increased up to 95%, and early signs of a forthcoming PT were identified 10±8 days prior to its clinical manifestation. This study demonstrates high reliability and the potential for effective clinical translation of this prognostic tool.
2022
Inglese
Springer
15
2
408
415
Epub ahead of print
Esperti anonimi
Internazionale
Circadian rhythm
Left ventricular assist device
Log files
Pump thrombosis
Time-frequency analysis
No
Real-Time Analysis of the Log Files of the HeartWare Continuous-Flow Left Ventricular Assist Device for the Early Diagnosis of Pump Thrombosis: a Step Forward Toward Clinical Translation / Consolo, F.; Pappalardo, F.. - In: JOURNAL OF CARDIOVASCULAR TRANSLATIONAL RESEARCH. - ISSN 1937-5387. - 15:2(2022), pp. 408-415. [Epub ahead of print] [10.1007/s12265-021-10157-1]
none
2
info:eu-repo/semantics/article
262
Consolo, F.; Pappalardo, F.
1 Contributo su Rivista::1.1 Articolo in rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/119155
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact