Background: Advanced maxillary atrophy is one of the most common clinical scenarios where implant placement could become difficult. Nevertheless, a volumetric evaluation using a suitable diagnostic software could facilitate the implant planning. The purpose of the present study is to suggest the potential application of the maxillary retro-canine area as the designated location for virtual tilted implants. Methods: A sample of Cone Beam Computed Tomography (CBCT) images from the Department of Dentistry (IRCSS San Raffaele, Milan, Italy) was evaluated. After a 3D anatomical evaluation, tilted implants were virtually positioned in the retro-canine regions. All the implants were inserted using the same procedure at 30◦ and 45◦ degrees of tilting. The length, palatal angulation and diameter of the placed implant were identified. Results: A total of 220 tilted implants were placed. An average implant measurement of 13.51 mm in length and 3.42 mm in diameter were calculated. Additionally, an average buccal–palatal angulation of 6◦ was identified. Upon statistical analysis, the implant length was found to be significantly higher at 45◦ degrees of mesio-distal angulation than at 30◦ degrees (<0.0001). Conclusions: A considerable number of patients show a significant degree of bone atrophy. The implant-supported treatment plan can rely on three-dimensional imaging of the residual bone as a guiding tool to establish the most effective implant position for each specific case. In this study, it was found that an implant could have a greater length if its mesio–distal angulation was more accentuated. In addition, owing to the volumetric evaluation, it was possible to virtually insert tilted implants in almost all of the cases of atrophy. This could lead clinicians to consider the retro-canine area as a viable place to insert a longer tilted implant.

Virtual implant rehabilitation of the severely atrophic maxilla: A radiographic study

Mottola F.;Vinci R.
2020-01-01

Abstract

Background: Advanced maxillary atrophy is one of the most common clinical scenarios where implant placement could become difficult. Nevertheless, a volumetric evaluation using a suitable diagnostic software could facilitate the implant planning. The purpose of the present study is to suggest the potential application of the maxillary retro-canine area as the designated location for virtual tilted implants. Methods: A sample of Cone Beam Computed Tomography (CBCT) images from the Department of Dentistry (IRCSS San Raffaele, Milan, Italy) was evaluated. After a 3D anatomical evaluation, tilted implants were virtually positioned in the retro-canine regions. All the implants were inserted using the same procedure at 30◦ and 45◦ degrees of tilting. The length, palatal angulation and diameter of the placed implant were identified. Results: A total of 220 tilted implants were placed. An average implant measurement of 13.51 mm in length and 3.42 mm in diameter were calculated. Additionally, an average buccal–palatal angulation of 6◦ was identified. Upon statistical analysis, the implant length was found to be significantly higher at 45◦ degrees of mesio-distal angulation than at 30◦ degrees (<0.0001). Conclusions: A considerable number of patients show a significant degree of bone atrophy. The implant-supported treatment plan can rely on three-dimensional imaging of the residual bone as a guiding tool to establish the most effective implant position for each specific case. In this study, it was found that an implant could have a greater length if its mesio–distal angulation was more accentuated. In addition, owing to the volumetric evaluation, it was possible to virtually insert tilted implants in almost all of the cases of atrophy. This could lead clinicians to consider the retro-canine area as a viable place to insert a longer tilted implant.
2020
CBCT
Implant planning
Implant rehabilitation
Maxillary atrophy
Oral surgery
Tilted implants
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/120333
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 6
social impact