Objective: We compared the theoretical anatomic feasibility of endovascular treatment of thoracoabdominal aortic aneurysms (TAAAs) with three off-the-shelf multibranched stent-grafts: t-Branch (Zenith t-Branch; Cook Medical, Bloomington, Ind), Gore Excluder thoracoabdominal branch endoprosthesis (TAMBE; W. L. Gore & Associates, Flagstaff, Ariz), and E-nside (E-nside multibranch stent graft system; Jotec GmbH, Hechingen, Germany). Methods: Computed tomography scans of patients with degenerative TAAAs treated from 2007 to 2019 were reviewed, and the anatomic feasibility of the multibranched stent-grafts was assessed according to the manufacturer's instructions for use. The anatomic factors determining the overall feasibility were divided into access feasibility, aortic feasibility, and visceral vessel feasibility. Results: Degenerative TAAAs in 268 patients were analyzed. The overall feasibility did not differ significantly (TAMBE, 33%; t-Branch, 39%; E-nside, 43%; P =.271). Access, aortic, and visceral vessel feasibility alone excluded 18% to 22%, 35% to 49% and 21% to 26% of the patients respectively. The only significant difference between the devices was in aortic feasibility (P =.005), which was more frequently limited by the proximal aortic neck diameter in the TAMBE cohort and the inner visceral aortic diameter in the t-Branch cohort. The overall treatment feasibility using any of the three devices would have been 58%. Conclusions: The new investigational off-the-shelf multibranched stent-grafts did not significantly improve the theoretical applicability in an extensive cohort of patients with TAAAs. Improvements are warranted to increase their overall feasibility.

Comparison of anatomic feasibility of three different multibranched off-the-shelf stent-grafts designed for thoracoabdominal aortic aneurysms / Bertoglio, L.; Grandi, A.; Carta, N.; Cambiaghi, T.; Bilman, V.; Melissano, G.; Chiesa, R.. - In: JOURNAL OF VASCULAR SURGERY. - ISSN 0741-5214. - 74:5(2021), pp. 1472-1482.e4. [Epub ahead of print] [10.1016/j.jvs.2021.04.066]

Comparison of anatomic feasibility of three different multibranched off-the-shelf stent-grafts designed for thoracoabdominal aortic aneurysms

Bertoglio L.;Carta N.;Melissano G.;Chiesa R.
2021-01-01

Abstract

Objective: We compared the theoretical anatomic feasibility of endovascular treatment of thoracoabdominal aortic aneurysms (TAAAs) with three off-the-shelf multibranched stent-grafts: t-Branch (Zenith t-Branch; Cook Medical, Bloomington, Ind), Gore Excluder thoracoabdominal branch endoprosthesis (TAMBE; W. L. Gore & Associates, Flagstaff, Ariz), and E-nside (E-nside multibranch stent graft system; Jotec GmbH, Hechingen, Germany). Methods: Computed tomography scans of patients with degenerative TAAAs treated from 2007 to 2019 were reviewed, and the anatomic feasibility of the multibranched stent-grafts was assessed according to the manufacturer's instructions for use. The anatomic factors determining the overall feasibility were divided into access feasibility, aortic feasibility, and visceral vessel feasibility. Results: Degenerative TAAAs in 268 patients were analyzed. The overall feasibility did not differ significantly (TAMBE, 33%; t-Branch, 39%; E-nside, 43%; P =.271). Access, aortic, and visceral vessel feasibility alone excluded 18% to 22%, 35% to 49% and 21% to 26% of the patients respectively. The only significant difference between the devices was in aortic feasibility (P =.005), which was more frequently limited by the proximal aortic neck diameter in the TAMBE cohort and the inner visceral aortic diameter in the t-Branch cohort. The overall treatment feasibility using any of the three devices would have been 58%. Conclusions: The new investigational off-the-shelf multibranched stent-grafts did not significantly improve the theoretical applicability in an extensive cohort of patients with TAAAs. Improvements are warranted to increase their overall feasibility.
2021
Aneurysm
Aorta
Endovascular
Feasibility
Multibranched
Off-the-shelf
Thoracoabdominal
Aged
Aortic Aneurysm, Thoracic
Aortography
Blood Vessel Prosthesis Implantation
Computed Tomography Angiography
Databases, Factual
Endovascular Procedures
Feasibility Studies
Female
Humans
Male
Middle Aged
Prosthesis Design
Retrospective Studies
Time Factors
Treatment Outcome
Blood Vessel Prosthesis
Stents
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/122377
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 52
  • ???jsp.display-item.citation.isi??? 41
social impact