Background: Panoramic radiography creates distortion in teeth position and inclination especially in lateral areas of the arches due to acquisition and curved shape of dental arch. The aim of this study was to evaluate panoramic distortion compared to cone-beam computed tomography. Methods: Mesiodistal angulations were measured on panoramic radiography. Mesiodistal angulations and buccolingual inclinations of the teeth were determined on cone-beam computed tomography scans. The previous measurements were then compared through Pearson correlation coefficient. Results: The results showed higher correlation between mesiodistal 2D angulation and buccolingual 3D inclination, especially for first premolars, rather than between mesiodistal angulations measured in 2D and 3D. Conclusion: Especially for the lateral areas of the dental arches, root mesiodistal angulation measured on panoramic radiography is not reliable; in fact, it is greatly influenced by buccolingual inclination. Therefore, clinical evaluation is highly recommended with panoramic radiography to provide correct diagnosis and the most satisfactory results.

Correlation between Mesio-Distal Angulation and Bucco.-Lingual Inclination of First and Second Maxillary Premolars Evaluated with Panoramic Radiography and Cone-Beam Computed Tomography / Fontana, M.; Fastuca, R.; Zecca, P. A.; Nucera, R.; Militi, A.; Lucchese, A.; Portelli, M.; Caprioglio, A.. - In: APPLIED SCIENCES. - ISSN 1454-5101. - 11:5(2021), pp. 1-10. [10.3390/app11052374]

Correlation between Mesio-Distal Angulation and Bucco.-Lingual Inclination of First and Second Maxillary Premolars Evaluated with Panoramic Radiography and Cone-Beam Computed Tomography

Lucchese A.;
2021-01-01

Abstract

Background: Panoramic radiography creates distortion in teeth position and inclination especially in lateral areas of the arches due to acquisition and curved shape of dental arch. The aim of this study was to evaluate panoramic distortion compared to cone-beam computed tomography. Methods: Mesiodistal angulations were measured on panoramic radiography. Mesiodistal angulations and buccolingual inclinations of the teeth were determined on cone-beam computed tomography scans. The previous measurements were then compared through Pearson correlation coefficient. Results: The results showed higher correlation between mesiodistal 2D angulation and buccolingual 3D inclination, especially for first premolars, rather than between mesiodistal angulations measured in 2D and 3D. Conclusion: Especially for the lateral areas of the dental arches, root mesiodistal angulation measured on panoramic radiography is not reliable; in fact, it is greatly influenced by buccolingual inclination. Therefore, clinical evaluation is highly recommended with panoramic radiography to provide correct diagnosis and the most satisfactory results.
2021
cone-beam computed tomography
orthodontic treatment
panoramic radiography
File in questo prodotto:
File Dimensione Formato  
7.pdf

accesso aperto

Tipologia: PDF editoriale (versione pubblicata dall'editore)
Licenza: Creative commons
Dimensione 7.33 MB
Formato Adobe PDF
7.33 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/122396
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact