Background: Although the European Organisation for Research and Treatment of Cancer (EORTC) QLQ-PAN26 is widely used to assess health-related quality of life (HRQoL), its group-level minimal important difference (MID) and individual-level responder definition (RD) are not established; we calculated MID and RD using HRQoL data from the APACT trial in patients with surgically resected pancreatic cancer who received adjuvant chemotherapy. Methods: HRQoL was assessed using EORTC QLQ-C30 and QLQ-PAN26 at baseline, during treatment, at end of treatment, and during follow-up. Distribution-based MIDs were estimated using 0.5 × baseline standard deviation (SD) and reliability-based (intraclass correlation) standard error of measurement (SEM). Anchor-based MIDs and RDs (anchor, QLQ-C30 overall health) were estimated using a linear mixed model. Results: Overall, 772 patients completed the baseline assessment. Distribution-based MIDs (0.5 × SD) for QLQ-PAN26 scales ranged from 12 to 13, except hepatic symptoms (≈8), pancreatic pain (≈10), and sexual dysfunction (≈17); those for stand-alone items ranged from 12 to 16. The SEM values were similar. Among scales/items sufficiently correlated (r > 0.30) with the anchor, MIDs ranged from 5 to 9. Within-patient QLQ-PAN26 RD estimates varied by direction (deterioration vs. improvement) and scale/item, but all values were lower than the true possible within-patient change (e.g. 16.7 points for a two-item scale) given a one-category change on the raw scale. Conclusions: Compared with distribution-based MIDs, anchor-based MIDs were twice as sensitive in detecting group-level changes in QLQ-PAN26 scales/items. For interpreting clinically meaningful change, RDs cannot be less than the true minimum of the scale. The group-level MID may help clinicians/researchers interpret HRQoL changes. Trial registration: ClinicalTrials.gov NCT01964430; Eudra CT 2013-003398-91.

Evaluation of Minimal Important Difference and Responder Definition in the EORTC QLQ-PAN26 Module for Assessing Health-Related Quality of Life in Patients with Surgically Resected Pancreatic Adenocarcinoma / Reni, M.; Braverman, J.; Hendifar, A.; Li, C. -P.; Macarulla, T.; Oh, D. -Y.; Riess, H.; Tempero, M.; Lu, B.; Marcus, J.; Joshi, N.; Botteman, M.; Dueck, A. C.. - In: ANNALS OF SURGICAL ONCOLOGY. - ISSN 1068-9265. - 28:12(2021), pp. 7545-7554. [10.1245/s10434-021-09816-z]

Evaluation of Minimal Important Difference and Responder Definition in the EORTC QLQ-PAN26 Module for Assessing Health-Related Quality of Life in Patients with Surgically Resected Pancreatic Adenocarcinoma

Reni M.
Primo
;
2021-01-01

Abstract

Background: Although the European Organisation for Research and Treatment of Cancer (EORTC) QLQ-PAN26 is widely used to assess health-related quality of life (HRQoL), its group-level minimal important difference (MID) and individual-level responder definition (RD) are not established; we calculated MID and RD using HRQoL data from the APACT trial in patients with surgically resected pancreatic cancer who received adjuvant chemotherapy. Methods: HRQoL was assessed using EORTC QLQ-C30 and QLQ-PAN26 at baseline, during treatment, at end of treatment, and during follow-up. Distribution-based MIDs were estimated using 0.5 × baseline standard deviation (SD) and reliability-based (intraclass correlation) standard error of measurement (SEM). Anchor-based MIDs and RDs (anchor, QLQ-C30 overall health) were estimated using a linear mixed model. Results: Overall, 772 patients completed the baseline assessment. Distribution-based MIDs (0.5 × SD) for QLQ-PAN26 scales ranged from 12 to 13, except hepatic symptoms (≈8), pancreatic pain (≈10), and sexual dysfunction (≈17); those for stand-alone items ranged from 12 to 16. The SEM values were similar. Among scales/items sufficiently correlated (r > 0.30) with the anchor, MIDs ranged from 5 to 9. Within-patient QLQ-PAN26 RD estimates varied by direction (deterioration vs. improvement) and scale/item, but all values were lower than the true possible within-patient change (e.g. 16.7 points for a two-item scale) given a one-category change on the raw scale. Conclusions: Compared with distribution-based MIDs, anchor-based MIDs were twice as sensitive in detecting group-level changes in QLQ-PAN26 scales/items. For interpreting clinically meaningful change, RDs cannot be less than the true minimum of the scale. The group-level MID may help clinicians/researchers interpret HRQoL changes. Trial registration: ClinicalTrials.gov NCT01964430; Eudra CT 2013-003398-91.
2021
Humans
Quality of Life
Reproducibility of Results
Surveys and Questionnaires
Adenocarcinoma
Pancreatic Neoplasms
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/126381
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact