Background: Glucose sensors consist of real-time continuous glucose monitoring (rtCGM) and intermittently scanned CGM (isCGM). Their clinical use has been widely increasing during the past 5 years. The aim of this study is to evaluate percentage of time in range (TIR) in a large group of children with type 1 diabetes (T1D) using glucose sensors with nonautomated insulin delivery systems, in a real-world setting. Methods: An 11-center cross-sectional study was conducted during January-May 2019. Children with T1D <18 years, all using rtCGM or isCGM for >1 year, treated with multiple daily injections (MDI) or nonautomated insulin pump (IP), were recruited consecutively. Clinical data, HbA1c measurement, and CGM downloaded data were collected by each center and included in a centralized database for the analysis. Glucose metrics of four treatment strategies were analyzed: isCGM-MDI, rtCGM-MDI, isCGM-IP, and rtCGM-IP. Results: Data from 666 children with T1D (51% male and 49% female), median age 12 years, diabetes duration 5 years, were analyzed. An rtCGM was used by 51% of the participants, and a nonautomated IP by 46%. For isCGM-MDI, rtCGM-MDI, isCGM-IP, and rtCGM-IP, the median TIR 70-180 mg/dL values were 49%, 56%, 56%, and 61% (P < 0.001), respectively; HbA1c 7.6%, 7.5%, 7.3%, and 7.3% (P < 0.001), respectively. Use of rtCGM was associated with significant lower time below target range <70 mg/dL and reduced the percentage coefficient of variation of glucose (%CV), independently by the insulin delivery system used. Conclusions: Among nonautomated insulin delivery strategies, simultaneous use of rtCGM and IP was associated with higher percentage of TIR, lower time above range >180 mg/dL and lower HbA1c. If there are no barriers, an upgrade of the treatment strategy with a higher performing technology should be offered to all children who do not achieve blood glucose metrics within the suggested range.
Time in Range in Children with Type 1 Diabetes Using Treatment Strategies Based on Nonautomated Insulin Delivery Systems in the Real World / Cherubini, V., Bonfanti, R., Casertano, A., De Nitto, E., Iannilli, A., Lombardo, F., Maltoni, G., Marigliano, M., Bassi, M., Minuto, N., Mozzillo, E., Rabbone, I., Rapini, N., Rigamonti, A., Salzano, G., Scaramuzza, A., Schiaffini, R., Tinti, D., Toni, S., Zagaroli, L., et al.. - In: DIABETES TECHNOLOGY & THERAPEUTICS. - ISSN 1520-9156. - 22:7(2020), pp. 509-515. [10.1089/dia.2020.0031]
Time in Range in Children with Type 1 Diabetes Using Treatment Strategies Based on Nonautomated Insulin Delivery Systems in the Real World
Bonfanti R.Secondo
;
2020-01-01
Abstract
Background: Glucose sensors consist of real-time continuous glucose monitoring (rtCGM) and intermittently scanned CGM (isCGM). Their clinical use has been widely increasing during the past 5 years. The aim of this study is to evaluate percentage of time in range (TIR) in a large group of children with type 1 diabetes (T1D) using glucose sensors with nonautomated insulin delivery systems, in a real-world setting. Methods: An 11-center cross-sectional study was conducted during January-May 2019. Children with T1D <18 years, all using rtCGM or isCGM for >1 year, treated with multiple daily injections (MDI) or nonautomated insulin pump (IP), were recruited consecutively. Clinical data, HbA1c measurement, and CGM downloaded data were collected by each center and included in a centralized database for the analysis. Glucose metrics of four treatment strategies were analyzed: isCGM-MDI, rtCGM-MDI, isCGM-IP, and rtCGM-IP. Results: Data from 666 children with T1D (51% male and 49% female), median age 12 years, diabetes duration 5 years, were analyzed. An rtCGM was used by 51% of the participants, and a nonautomated IP by 46%. For isCGM-MDI, rtCGM-MDI, isCGM-IP, and rtCGM-IP, the median TIR 70-180 mg/dL values were 49%, 56%, 56%, and 61% (P < 0.001), respectively; HbA1c 7.6%, 7.5%, 7.3%, and 7.3% (P < 0.001), respectively. Use of rtCGM was associated with significant lower time below target range <70 mg/dL and reduced the percentage coefficient of variation of glucose (%CV), independently by the insulin delivery system used. Conclusions: Among nonautomated insulin delivery strategies, simultaneous use of rtCGM and IP was associated with higher percentage of TIR, lower time above range >180 mg/dL and lower HbA1c. If there are no barriers, an upgrade of the treatment strategy with a higher performing technology should be offered to all children who do not achieve blood glucose metrics within the suggested range.| File | Dimensione | Formato | |
|---|---|---|---|
|
cherubini-et-al-2020-time-in-range-in-children-with-type-1-diabetes-using-treatment-strategies-based-on-nonautomated.pdf
solo gestori archivio
Tipologia:
PDF editoriale (versione pubblicata dall'editore)
Licenza:
Tutti i diritti riservati
Dimensione
362.19 kB
Formato
Adobe PDF
|
362.19 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.