The purpose of this study was to develop a reliable method of EEG analysis during carotid endarterectomy. EEGs of 104 patients under general anesthesia were processed by three different methods: a) 'on-line' visual analysis during surgery, b) 'off-line' visual analysis in laboratory, and c) computer analysis. To identify pathological EEGs, variability and asymmetry indexes of the 0.5-3.5 Hz and 8-15 Hz bands, absolute power and variability indexes of spectral edge frequency (SEF), and main dominant frequency were evaluated. On-line visual analysis showed clamp-related modifications in 29 EEGs (27.9%). Off-line visual analysis detected 24 pathological EEGs (23.1%): 18 with major changes and 6 with moderate changes. Computer analysis showed 21 EEGs (20.19%)with at least one altered index and 7 (6.7%) with altered variability for both SEF and 8-15 Hz power. The statistical analysis was significant for SEF variability and for 8-15 Hz power variability and asymmetry (P < 0.0001, analysis of variance test). While SEF and 8-15 Hz power variability did not appear influenced by anesthesia and single electrode artifacts, 8-15 Hz power asymmetry index was confounded by the presence of contralateral internal carotid occlusion. The data show that the use of these spectral indexes adds objective information to visual analysis, supporting and making easier intraoperative strategies. Their routine clinical use does not involve additional costs remaining technical requirements unchanged compared to traditional recording.

Computer-assisted EEG monitoring during carotid endarterectomy

Chiesa R;Comi G
Ultimo
2000-01-01

Abstract

The purpose of this study was to develop a reliable method of EEG analysis during carotid endarterectomy. EEGs of 104 patients under general anesthesia were processed by three different methods: a) 'on-line' visual analysis during surgery, b) 'off-line' visual analysis in laboratory, and c) computer analysis. To identify pathological EEGs, variability and asymmetry indexes of the 0.5-3.5 Hz and 8-15 Hz bands, absolute power and variability indexes of spectral edge frequency (SEF), and main dominant frequency were evaluated. On-line visual analysis showed clamp-related modifications in 29 EEGs (27.9%). Off-line visual analysis detected 24 pathological EEGs (23.1%): 18 with major changes and 6 with moderate changes. Computer analysis showed 21 EEGs (20.19%)with at least one altered index and 7 (6.7%) with altered variability for both SEF and 8-15 Hz power. The statistical analysis was significant for SEF variability and for 8-15 Hz power variability and asymmetry (P < 0.0001, analysis of variance test). While SEF and 8-15 Hz power variability did not appear influenced by anesthesia and single electrode artifacts, 8-15 Hz power asymmetry index was confounded by the presence of contralateral internal carotid occlusion. The data show that the use of these spectral indexes adds objective information to visual analysis, supporting and making easier intraoperative strategies. Their routine clinical use does not involve additional costs remaining technical requirements unchanged compared to traditional recording.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/13677
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 17
social impact