BACKGROUND: Restenosis after implantation of drug-eluting stents (DES) is a rare phenomenon, occurring more frequently peri-stent.METHODS AND RESULTS: We evaluated the pattern of restenosis occurring after implantation of DES in unselected lesions. From April 15 to December 6, 2002, we treated 368 patients with 735 lesions by using 841 rapamycin-eluting stents (Cypher, Cordis, a Johnson & Johnson Company). Mean baseline lesion length was 17.48+/-12.19 mm, and mean stent length was 27.59+/-14.02 mm. Follow-up ischemia-driven angiography was performed in 24 patients. Eleven patients had angiographic restenosis (> or =50% diameter stenosis) in 14 stented segments (stent and 5 mm proximal and distal to the stent). The pattern of restenosis in all 14 stented segments was focal, and in 6 of them it was multifocal, occurring inside the stents. Mean length of restenotic lesions was 5.62+/-1.90 mm, with a range from 2.54 to 8.44 mm. One multifocal restenosis involved also the distal stent margin. Intravascular ultrasound evaluation at follow-up, performed in 2 patients, showed significant lumen obstruction attributable to in-stent hyperplasia in both cases. Individual cases can be viewed in the Data Supplement.CONCLUSIONS: The pattern of restenotic lesions after rapamycin-eluting stent implantation was focal and mostly inside the stent.

Preliminary observations regarding angiographic pattern of restenosis after rapamycin-eluting stent implantation / Colombo, Antonio; Orlic, Dejan; Stankovic, Goran; Corvaja, Nicola; Spanos, Vassilis; Montorfano, M; Liistro, Francesco; Carlino, Mauro; Airoldi, Flavio; Chieffo, Alaide; Di Mario, Carlo. - In: CIRCULATION. - ISSN 1524-4539. - (2003). [10.1161/01.CIR.0000070592.04766.36]

Preliminary observations regarding angiographic pattern of restenosis after rapamycin-eluting stent implantation

Montorfano M;Chieffo Alaide;
2003-01-01

Abstract

BACKGROUND: Restenosis after implantation of drug-eluting stents (DES) is a rare phenomenon, occurring more frequently peri-stent.METHODS AND RESULTS: We evaluated the pattern of restenosis occurring after implantation of DES in unselected lesions. From April 15 to December 6, 2002, we treated 368 patients with 735 lesions by using 841 rapamycin-eluting stents (Cypher, Cordis, a Johnson & Johnson Company). Mean baseline lesion length was 17.48+/-12.19 mm, and mean stent length was 27.59+/-14.02 mm. Follow-up ischemia-driven angiography was performed in 24 patients. Eleven patients had angiographic restenosis (> or =50% diameter stenosis) in 14 stented segments (stent and 5 mm proximal and distal to the stent). The pattern of restenosis in all 14 stented segments was focal, and in 6 of them it was multifocal, occurring inside the stents. Mean length of restenotic lesions was 5.62+/-1.90 mm, with a range from 2.54 to 8.44 mm. One multifocal restenosis involved also the distal stent margin. Intravascular ultrasound evaluation at follow-up, performed in 2 patients, showed significant lumen obstruction attributable to in-stent hyperplasia in both cases. Individual cases can be viewed in the Data Supplement.CONCLUSIONS: The pattern of restenotic lesions after rapamycin-eluting stent implantation was focal and mostly inside the stent.
File in questo prodotto:
File Dimensione Formato  
19-colombo.pdf

solo gestori archivio

Tipologia: PDF editoriale (versione pubblicata dall'editore)
Licenza: Copyright dell'editore
Dimensione 153.75 kB
Formato Adobe PDF
153.75 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/141569
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 196
  • ???jsp.display-item.citation.isi??? 151
social impact