We evaluated the safety and effectiveness of postdilating a 3.0 mm sirolimus-eluting stents (SESs; six cells) with a 3.5-4.0 mm balloon. We identified 254 consecutive patients who underwent percutaneous coronary interventions using SESs with a nominal diameter of 3.0 mm (six cells). Patients were divided into two groups based on whether they were subsequently postdilated with a 3.0 mm (group 1: 168 patients, 251 lesions) or a 3.5-4 mm balloon (group 2: 86 patients, 102 lesions). There were no significant differences regarding the incidence of in-hospital and long-term follow-up. Angiographic follow-up was available in 72% and 74% of groups 1 and 2, respectively. The two groups had no significant differences regarding late lumen loss (0.51 +/- 0.36 vs. 0.52 +/- 0.33; P = 0.3) and binary restenosis rates (10.7% vs. 8.8%; P = 0.1). Six-month clinical follow-up was available in all patients. At long-term follow-up (mean: 10.6 +/- 3.7 for group 1 and 11.3 +/- 3.9 months for group 2), there were no significant differences between the two groups regarding major adverse cardiac events (8.9% vs. 9.2%; P = 0.9). Implantation of a 3.0 mm SES with postdilation with a 3.5-4 mm balloon did not result in any significant difference in complications, in-hospital non-Q-wave myocardial infarction, binary restenosis, or target lesion revascularization. These data should lessen concern that overdilation may dilute the beneficial effects of SESs.

Is overdilatation of 3.0 mm sirolimus-eluting stent associated with a higher restenosis rate? / Iakovou, Ioannis; Stankovic, Goran; Montorfano, M; Airoldi, Flavio; Chieffo, Alaide; Sangiorgi Giuseppe, M.; Carlino, Mauro; Corvaja, Nicola; Iassen, Michev; Rogacka, Renata; Vitrella, Giancarlo; Colombo, Antonio. - In: CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS. - ISSN 1522-1946. - (2005). [10.1002/ccd.20276]

Is overdilatation of 3.0 mm sirolimus-eluting stent associated with a higher restenosis rate?

Montorfano M;Chieffo Alaide;
2005-01-01

Abstract

We evaluated the safety and effectiveness of postdilating a 3.0 mm sirolimus-eluting stents (SESs; six cells) with a 3.5-4.0 mm balloon. We identified 254 consecutive patients who underwent percutaneous coronary interventions using SESs with a nominal diameter of 3.0 mm (six cells). Patients were divided into two groups based on whether they were subsequently postdilated with a 3.0 mm (group 1: 168 patients, 251 lesions) or a 3.5-4 mm balloon (group 2: 86 patients, 102 lesions). There were no significant differences regarding the incidence of in-hospital and long-term follow-up. Angiographic follow-up was available in 72% and 74% of groups 1 and 2, respectively. The two groups had no significant differences regarding late lumen loss (0.51 +/- 0.36 vs. 0.52 +/- 0.33; P = 0.3) and binary restenosis rates (10.7% vs. 8.8%; P = 0.1). Six-month clinical follow-up was available in all patients. At long-term follow-up (mean: 10.6 +/- 3.7 for group 1 and 11.3 +/- 3.9 months for group 2), there were no significant differences between the two groups regarding major adverse cardiac events (8.9% vs. 9.2%; P = 0.9). Implantation of a 3.0 mm SES with postdilation with a 3.5-4 mm balloon did not result in any significant difference in complications, in-hospital non-Q-wave myocardial infarction, binary restenosis, or target lesion revascularization. These data should lessen concern that overdilation may dilute the beneficial effects of SESs.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/142987
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 11
social impact