Despite encouraging results from randomized trials, concerns exist about long-term results of sirolimus-eluting stent implantation. We sought to determine whether in-stent restenosis occurring >1 year ("late") after sirolimus-eluting stent implantation is a real clinical entity. We analyzed data on all sirolimus-eluting stents implanted in our institution before March 2003. During the study period 928 lesions in 433 patients were treated. Angiographic follow-up was performed in 306 patients (70.6%) with 679 lesions (73.2%). Angiography after 1 year was performed only in symptomatic patients. We considered restenosis "early" if it occurred during the first year and late if after 1 year. Late restenosis required demonstration of a widely patent stent at 6 to 9 months, with repeat angiography after 1 year demonstrating restenosis. Restenosis occurred in 160 lesions overall (23.5%). Of the 31 (4.6%) that were documented after 1 year, 13 were excluded from analysis due to absence of 6- to 9-month angiography; the remaining 18 (2.6%, 1.7 to 4.2) fulfilled our criteria for late restenosis (median time of documentation 607 days, interquartile range 511 to 923). In conclusion, late restenosis is an infrequent but real entity; its existence implies we should not discount the possibility of restenosis as the cause of symptoms that develop >1 year after sirolimus-eluting stent implantation.

Late restenosis following sirolimus-eluting stent implantation / Cosgrave, John; Corbett Simon, J.; Melzi, Gloria; Babic, Rade; Biondi-Zoccai Giuseppe, G. L.; Airoldi, Flavio; Chieffo, Alaide; Sangiorgi Giuseppe, M.; Montorfano, M; Michev, Iassen; Carlino, Mauro; Colombo, Antonio. - In: THE AMERICAN JOURNAL OF CARDIOLOGY. - ISSN 0002-9149. - (2007). [10.1016/j.amjcard.2007.01.070]

Late restenosis following sirolimus-eluting stent implantation

Chieffo Alaide;Montorfano M;
2007-01-01

Abstract

Despite encouraging results from randomized trials, concerns exist about long-term results of sirolimus-eluting stent implantation. We sought to determine whether in-stent restenosis occurring >1 year ("late") after sirolimus-eluting stent implantation is a real clinical entity. We analyzed data on all sirolimus-eluting stents implanted in our institution before March 2003. During the study period 928 lesions in 433 patients were treated. Angiographic follow-up was performed in 306 patients (70.6%) with 679 lesions (73.2%). Angiography after 1 year was performed only in symptomatic patients. We considered restenosis "early" if it occurred during the first year and late if after 1 year. Late restenosis required demonstration of a widely patent stent at 6 to 9 months, with repeat angiography after 1 year demonstrating restenosis. Restenosis occurred in 160 lesions overall (23.5%). Of the 31 (4.6%) that were documented after 1 year, 13 were excluded from analysis due to absence of 6- to 9-month angiography; the remaining 18 (2.6%, 1.7 to 4.2) fulfilled our criteria for late restenosis (median time of documentation 607 days, interquartile range 511 to 923). In conclusion, late restenosis is an infrequent but real entity; its existence implies we should not discount the possibility of restenosis as the cause of symptoms that develop >1 year after sirolimus-eluting stent implantation.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/143137
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 31
social impact