Interest in the use of mechanical circulatory support for patients presenting with cardiogenic shock is growing rapidly. The Impella (Abiomed Inc), a microaxial, continuous-flow, short-term, ventricular assist device (VAD), requires meticulous postimplantation management. Because systemic anticoagulation is needed to prevent pump thrombosis, patients are exposed to increased bleeding risk, further aggravated by sepsis, thrombocytopenia, and high shear stress–induced acquired von Willebrand syndrome. The precarious balance between bleeding and thrombosis in percutaneous VAD–supported cardiogenic shock patients is often the main reason that patient outcomes are jeopardized, and there is a lack of data addressing optimal anticoagulation management strategies during percutaneous VAD support. Here, we present a parallel anti-Factor Xa/activated partial thromboplastin time-guided anticoagulation algorithm and discuss pitfalls of heparin monitoring in critically ill patients. This review will guide physicians toward a more standardized (anti)coagulation approach to tackle device-related morbidity and mortality in this critically ill patient group.

Anticoagulation for Percutaneous Ventricular Assist Device-Supported Cardiogenic Shock: JACC Review Topic of the Week / Vandenbriele, C.; Arachchillage, D. J.; Frederiks, P.; Giustino, G.; Gorog, D. A.; Gramegna, M.; Janssens, S.; Meyns, B.; Polzin, A.; Scandroglio, M.; Schrage, B.; Stone, G. W.; Tavazzi, G.; Vanassche, T.; Vranckx, P.; Westermann, D.; Price, S.; Chieffo, A.. - In: JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY. - ISSN 0735-1097. - 79:19(2022), pp. 1949-1962. [10.1016/j.jacc.2022.02.052]

Anticoagulation for Percutaneous Ventricular Assist Device-Supported Cardiogenic Shock: JACC Review Topic of the Week

Chieffo A.
Ultimo
2022-01-01

Abstract

Interest in the use of mechanical circulatory support for patients presenting with cardiogenic shock is growing rapidly. The Impella (Abiomed Inc), a microaxial, continuous-flow, short-term, ventricular assist device (VAD), requires meticulous postimplantation management. Because systemic anticoagulation is needed to prevent pump thrombosis, patients are exposed to increased bleeding risk, further aggravated by sepsis, thrombocytopenia, and high shear stress–induced acquired von Willebrand syndrome. The precarious balance between bleeding and thrombosis in percutaneous VAD–supported cardiogenic shock patients is often the main reason that patient outcomes are jeopardized, and there is a lack of data addressing optimal anticoagulation management strategies during percutaneous VAD support. Here, we present a parallel anti-Factor Xa/activated partial thromboplastin time-guided anticoagulation algorithm and discuss pitfalls of heparin monitoring in critically ill patients. This review will guide physicians toward a more standardized (anti)coagulation approach to tackle device-related morbidity and mortality in this critically ill patient group.
2022
anticoagulation management
bleeding
thrombosis
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0735109722044849-main.pdf

accesso aperto

Tipologia: PDF editoriale (versione pubblicata dall'editore)
Licenza: Creative commons
Dimensione 2.63 MB
Formato Adobe PDF
2.63 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/145299
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 53
  • ???jsp.display-item.citation.isi??? 46
social impact