OBJECTIVES. To evaluate the clinical outcome of a purpose-designed implant, placed in the upper premolar position of distally edentulous jaws, supporting a 3-unit cantilevered screw-retained prosthesis. MATERIALS AND METHODS. Sixteen patients received, in the upper premolar area, a single implant specifically designed to support a 3-unit distally cantilevered screw-retained prosthesis. Implants were loaded after 3 to 5 months of submerged healing, depending on bone density. Eight prostheses were made of metal-composite and eight of fibre-rein-forced composite at the discretion of the dentist. Outcome measures, evaluated by an independent assessor, were: prosthesis and implant failure, complications and peri-im-plant marginal bone level changes. RESULTS. No patient dropped out. No implant or prosthesis failed. Three (19%) patients were affected by complications. After 2 years the mean marginal bone loss was 0.45 mm. CONCLUSIONS. These short-term results suggest that a 3-unit distally cantilevered prostheses can be supported in the maxilla by a single, purpose-designed dental implant up to 2 years after loading. Proper studies with follow-ups of about 10 years are needed to ascertain the long-term prognosis of this treatment option.

SINGLE IMPLANTS SUPPORTING A 3-UNIT CANTILEVERED MAXILLARY PROSTHESIS: A PROSPECTIVE CASE SERIES WITH 2-YEAR FOLLOW-UP / Cannizzaro, G.; Felice, P.; Lazzarini, M.; Viola, P.; Sorce, G.; Ferri, V.; Esposito, M.. - In: CLINICAL TRIALS IN DENTISTRY. - 2:2(2020), pp. 63-70. [10.36130/CTD.03.2020.06]

SINGLE IMPLANTS SUPPORTING A 3-UNIT CANTILEVERED MAXILLARY PROSTHESIS: A PROSPECTIVE CASE SERIES WITH 2-YEAR FOLLOW-UP

Esposito M.
Ultimo
2020-01-01

Abstract

OBJECTIVES. To evaluate the clinical outcome of a purpose-designed implant, placed in the upper premolar position of distally edentulous jaws, supporting a 3-unit cantilevered screw-retained prosthesis. MATERIALS AND METHODS. Sixteen patients received, in the upper premolar area, a single implant specifically designed to support a 3-unit distally cantilevered screw-retained prosthesis. Implants were loaded after 3 to 5 months of submerged healing, depending on bone density. Eight prostheses were made of metal-composite and eight of fibre-rein-forced composite at the discretion of the dentist. Outcome measures, evaluated by an independent assessor, were: prosthesis and implant failure, complications and peri-im-plant marginal bone level changes. RESULTS. No patient dropped out. No implant or prosthesis failed. Three (19%) patients were affected by complications. After 2 years the mean marginal bone loss was 0.45 mm. CONCLUSIONS. These short-term results suggest that a 3-unit distally cantilevered prostheses can be supported in the maxilla by a single, purpose-designed dental implant up to 2 years after loading. Proper studies with follow-ups of about 10 years are needed to ascertain the long-term prognosis of this treatment option.
2020
cantilevered prosthesis
case series
dental implants
single implant
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/147356
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact