PURPOSE. To evaluate whether 4.0 x 4.0-mm dental implants could be viable alternatives to implants of length at least 8.5 mm when placed in posterior jaws with adequate bone volumes. MATERIALS AND METHODS. One hundred and fifty patients with posterior (premolar and molar areas) jaws having at least 12.5 mm bone height above the mandibular canal or 11.5 mm below the maxillary sinus, as applicable, were randomised according to a paral-lel-group design and received one to three 4.0 mm-long implants or one to three implants which were at least 8.5 mm-long at three treatment centres. All implants had a diameter of 4.0 mm. Implants were loaded with permanent screw-retained prostheses after 4 months. Patients were followed-up until 3-year post-loading, and outcome measures considered were prosthesis and implant failure, any complications, and changes in pe-ri-implant marginal bone levels. RESULTS. Seventy-five patients were randomly allocated to each group. Drop-outs at 3-year post-loading assessment were five patients from the long implant group and three from the short implant group. Up to 3 years post-loadings, three patients lost one 4.0 mm-long implant each, in comparison to two patients who lost one long implant each (difference in proportion =-0.013; 95% CI:-0.079 to 0.054; P = 1). All failures occurred before loading; failed implants were replaced, delaying delivery of two prostheses in each group by several months (difference in proportion = 0; 95% CI:-0.061 to 0.062; P = 1). Five short-implant patients experienced six complications versus the three complications seen in three long implant patients (difference in proportion =-0.026; 95% CI:-0.103 to 0.053; P = 0.719). There were no statistically significant differences between groups in prosthesis failures, implant failures or complications. Patients with short implants lost on average 0.55 mm of peri-implant bone, and patients with longer implants lost 0.61 mm. There were no statistically significant differences between short and long implants in bone level changes up to 3 years (mean difference = 0.05 mm; 95% CI:-0.05 to 0.16; P = 0.221). CONCLUSIONS. Outcomes 3 years after loading were similar with 4.0 x 4.0 mm-long implants and 8.5 x 4.0 mm or longer implants in posterior jaws, in the presence of adequate bone volumes. However, 5 to 10-year post-loading data will be necessary before reliable recommendations can be made. CONFLICT OF INTEREST STATEMENT. Global D (Brignais, France) partially supported this trial and donated the implants and prosthetic components. OsteoBiol (Tecnoss, Giaveno, Italy) donated the biomaterials used for bone augmentation. However, the data property belonged to the authors and neither Global D nor OsteoBiol interfered in any way with the conduct of the trial or the publication of the results.

POSTERIOR JAW REHABILITATION USING PARTIAL PROSTHESES SUPPORTED BY IMPLANTS 4.0 X 4.0 MM OR LONGER: THREE-YEAR POST-LOADING RESULTS OF A MULTICENTRE RANDOMISED CONTROLLED TRIAL / Barausse, C.; Felice, P.; Pistilli, R.; Buti, J.; Rcsed, M.; Esposito, M.. - In: CLINICAL TRIALS IN DENTISTRY. - 1:1(2019), pp. 25-36. [10.36130/CTD.01.2019.03]

POSTERIOR JAW REHABILITATION USING PARTIAL PROSTHESES SUPPORTED BY IMPLANTS 4.0 X 4.0 MM OR LONGER: THREE-YEAR POST-LOADING RESULTS OF A MULTICENTRE RANDOMISED CONTROLLED TRIAL

Esposito M.
Ultimo
2019-01-01

Abstract

PURPOSE. To evaluate whether 4.0 x 4.0-mm dental implants could be viable alternatives to implants of length at least 8.5 mm when placed in posterior jaws with adequate bone volumes. MATERIALS AND METHODS. One hundred and fifty patients with posterior (premolar and molar areas) jaws having at least 12.5 mm bone height above the mandibular canal or 11.5 mm below the maxillary sinus, as applicable, were randomised according to a paral-lel-group design and received one to three 4.0 mm-long implants or one to three implants which were at least 8.5 mm-long at three treatment centres. All implants had a diameter of 4.0 mm. Implants were loaded with permanent screw-retained prostheses after 4 months. Patients were followed-up until 3-year post-loading, and outcome measures considered were prosthesis and implant failure, any complications, and changes in pe-ri-implant marginal bone levels. RESULTS. Seventy-five patients were randomly allocated to each group. Drop-outs at 3-year post-loading assessment were five patients from the long implant group and three from the short implant group. Up to 3 years post-loadings, three patients lost one 4.0 mm-long implant each, in comparison to two patients who lost one long implant each (difference in proportion =-0.013; 95% CI:-0.079 to 0.054; P = 1). All failures occurred before loading; failed implants were replaced, delaying delivery of two prostheses in each group by several months (difference in proportion = 0; 95% CI:-0.061 to 0.062; P = 1). Five short-implant patients experienced six complications versus the three complications seen in three long implant patients (difference in proportion =-0.026; 95% CI:-0.103 to 0.053; P = 0.719). There were no statistically significant differences between groups in prosthesis failures, implant failures or complications. Patients with short implants lost on average 0.55 mm of peri-implant bone, and patients with longer implants lost 0.61 mm. There were no statistically significant differences between short and long implants in bone level changes up to 3 years (mean difference = 0.05 mm; 95% CI:-0.05 to 0.16; P = 0.221). CONCLUSIONS. Outcomes 3 years after loading were similar with 4.0 x 4.0 mm-long implants and 8.5 x 4.0 mm or longer implants in posterior jaws, in the presence of adequate bone volumes. However, 5 to 10-year post-loading data will be necessary before reliable recommendations can be made. CONFLICT OF INTEREST STATEMENT. Global D (Brignais, France) partially supported this trial and donated the implants and prosthetic components. OsteoBiol (Tecnoss, Giaveno, Italy) donated the biomaterials used for bone augmentation. However, the data property belonged to the authors and neither Global D nor OsteoBiol interfered in any way with the conduct of the trial or the publication of the results.
2019
posterior jaws
short dental implants
File in questo prodotto:
File Dimensione Formato  
Barausse_2019;01(1)25-36.pdf

solo gestori archivio

Tipologia: PDF editoriale (versione pubblicata dall'editore)
Licenza: Copyright dell'editore
Dimensione 651.65 kB
Formato Adobe PDF
651.65 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/148077
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? ND
social impact