Background and aim of the study: Edge-to-edge repair is an effective, recently introduced method to correct mitral insufficiency by suturing the leaflets at the site of regurgitation, though durability of the method has not been proven. To overcome the limitations of the clinical approach, simulations may be used to predict clinical outcome. In this study, the mechanical stress acting on leaflets imposed by the edge-to-edge suture was evaluated as a means of assessing the clinical risk of late fibrosis or tissue degeneration. Methods: A 3-D finite element simulated the stress pattern following edge-to-edge repair. Valve behavior was evaluated both in systole and in diastole. Both 4-mm. and 8-mm edge-to-edge sutures were simulated, as well as annular dilation. Results: Systolic simulations validated the model by comparison with previous models of the mitral valve. Diastolic stresses were negligible in the native mitral valve; after edge-to-edge repair (8-mm. suture), circumferential and longitudinal stress values were 308 kPa and 489 kPa, respectively, and comparable with those observed at systolic peak (449 kPa and 617 kPa, respectively). With a 4-mm suture, longitudinal stresses decreased both close to the suture (-41.5%) and in the annular region (-68%), while circumferential stresses increased (+37%) close to the suture and decreased (-27%) in the annular region. A 20%. dilation of the. annulus was followed by increased stresses in the annular region and close to the suture. Conclusion: Leaflet distortion and altered stress distribution occur on the leaflets after edge-to-edge repair. Diastolic peak stress values were comparable with those calculated in systole. The clinical implication is a doubled exposure of valve components to systolic stresses, as if the heart rate were doubled. The use of a prosthetic annuloplasty ring is favorable in the presence of annular dilation to reduce stresses acting on the leaflets after edge-to-edge repair.

3-D computational analysis of the stress distribution on the leaflets after edge-to-edge repair of mitral regurgitation

Maisano F;ALFIERI , OTTAVIO
2002-01-01

Abstract

Background and aim of the study: Edge-to-edge repair is an effective, recently introduced method to correct mitral insufficiency by suturing the leaflets at the site of regurgitation, though durability of the method has not been proven. To overcome the limitations of the clinical approach, simulations may be used to predict clinical outcome. In this study, the mechanical stress acting on leaflets imposed by the edge-to-edge suture was evaluated as a means of assessing the clinical risk of late fibrosis or tissue degeneration. Methods: A 3-D finite element simulated the stress pattern following edge-to-edge repair. Valve behavior was evaluated both in systole and in diastole. Both 4-mm. and 8-mm edge-to-edge sutures were simulated, as well as annular dilation. Results: Systolic simulations validated the model by comparison with previous models of the mitral valve. Diastolic stresses were negligible in the native mitral valve; after edge-to-edge repair (8-mm. suture), circumferential and longitudinal stress values were 308 kPa and 489 kPa, respectively, and comparable with those observed at systolic peak (449 kPa and 617 kPa, respectively). With a 4-mm suture, longitudinal stresses decreased both close to the suture (-41.5%) and in the annular region (-68%), while circumferential stresses increased (+37%) close to the suture and decreased (-27%) in the annular region. A 20%. dilation of the. annulus was followed by increased stresses in the annular region and close to the suture. Conclusion: Leaflet distortion and altered stress distribution occur on the leaflets after edge-to-edge repair. Diastolic peak stress values were comparable with those calculated in systole. The clinical implication is a doubled exposure of valve components to systolic stresses, as if the heart rate were doubled. The use of a prosthetic annuloplasty ring is favorable in the presence of annular dilation to reduce stresses acting on the leaflets after edge-to-edge repair.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/14924
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 87
  • ???jsp.display-item.citation.isi??? 71
social impact