Purpose: To compare the outcome of cross-arch prostheses supported either by 5 mm long or 11.5 mm long implants placed flapless and immediately restored with a metal-resin screw-retained cross-arch prostheses. Materials and methods: Thirty patients with edentulous or to-be- rendered edentulous mandibles, and 30 with edentulous maxillas, having sufficient bone to allow the placement of four and six implants respectively, of at least 11.5 mm long, were randomised according to a parallel group design into two equal groups and received either 5 mm or 11.5 mm long implants at one centre. Implants had a diameter of 5 mm, were to be placed flapless, and with an insertion torque of at least 50 Ncm. Mandibles received four implants between the mental foramina. Implants were to be immediately loaded with metal-resin definitive prostheses the same day as implant placement. Patients were followed to 5 years post-loading and the outcome measures were: prosthesis and implant failures, complications, and peri-implant marginal bone level changes. Results: Four patients per group dropped out. Two prostheses were remade, one on short maxillary implants and one on long mandibular implants (difference in proportions = 0; 95% CI: -0.15 to 0.15; P = 1.000). Three patients lost six short implants vs three patients who lost four long implants (difference in proportions = 0; 95% CI: -0.19 to 0.19; P = 1.000). Four short implant patients were affected by complications vs five patients with long implants (difference in proportions = 0.04; 95% CI: -0.17 to 0.25; P = 1.000). There were no statistically significant differences for prostheses failures, implant failures and complications. Patients with mandibular short implants lost on average 0.22 mm of peri-implant bone at 5 years while patients with long mandibular implants lost 0.83 mm. Patients with maxillary short implants lost on average 0.30 mm of peri-implant bone at 5 years and patients with long maxillary implants lost 0.89 mm. Short implants showed less bone loss when compared with long implants and the differences up to 5 years were statistically significant both in maxillae (mean difference = 0.59 mm, 95% CI: 0.33 to 0.86 mm, P < .0001) and in mandibles (mean difference = 0.61 mm, 95% CI: 0.36 to 0.86 mm, P < 0.0001). Conclusions: Flapless-placed 5 mm long implants achieved similar results as 11.5 mm long implants when supporting immediately loaded cross-arch prostheses both in maxillae and mandibles up to 5 years after loading. These results must be confirmed by other trials, and 10 years post-loading data is necessary before making reliable recommendations. Conflict of interest statement: This study was completely self-financed and no financial support has been sought or obtained, not even in the form of free materials.

Immediate loading of fixed cross-arch prostheses supported by flapless-placed 5 mm or 11.5 mm long implants: 5-year results from a randomised controlled trial / Cannizzaro, G.; Felice, P.; Ippolito, D. R.; Velasco-Ortega, E.; Esposito, M.. - In: EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY. - ISSN 1756-2406. - 11:3(2018), pp. 295-306.

Immediate loading of fixed cross-arch prostheses supported by flapless-placed 5 mm or 11.5 mm long implants: 5-year results from a randomised controlled trial

Esposito M.
Ultimo
2018-01-01

Abstract

Purpose: To compare the outcome of cross-arch prostheses supported either by 5 mm long or 11.5 mm long implants placed flapless and immediately restored with a metal-resin screw-retained cross-arch prostheses. Materials and methods: Thirty patients with edentulous or to-be- rendered edentulous mandibles, and 30 with edentulous maxillas, having sufficient bone to allow the placement of four and six implants respectively, of at least 11.5 mm long, were randomised according to a parallel group design into two equal groups and received either 5 mm or 11.5 mm long implants at one centre. Implants had a diameter of 5 mm, were to be placed flapless, and with an insertion torque of at least 50 Ncm. Mandibles received four implants between the mental foramina. Implants were to be immediately loaded with metal-resin definitive prostheses the same day as implant placement. Patients were followed to 5 years post-loading and the outcome measures were: prosthesis and implant failures, complications, and peri-implant marginal bone level changes. Results: Four patients per group dropped out. Two prostheses were remade, one on short maxillary implants and one on long mandibular implants (difference in proportions = 0; 95% CI: -0.15 to 0.15; P = 1.000). Three patients lost six short implants vs three patients who lost four long implants (difference in proportions = 0; 95% CI: -0.19 to 0.19; P = 1.000). Four short implant patients were affected by complications vs five patients with long implants (difference in proportions = 0.04; 95% CI: -0.17 to 0.25; P = 1.000). There were no statistically significant differences for prostheses failures, implant failures and complications. Patients with mandibular short implants lost on average 0.22 mm of peri-implant bone at 5 years while patients with long mandibular implants lost 0.83 mm. Patients with maxillary short implants lost on average 0.30 mm of peri-implant bone at 5 years and patients with long maxillary implants lost 0.89 mm. Short implants showed less bone loss when compared with long implants and the differences up to 5 years were statistically significant both in maxillae (mean difference = 0.59 mm, 95% CI: 0.33 to 0.86 mm, P < .0001) and in mandibles (mean difference = 0.61 mm, 95% CI: 0.36 to 0.86 mm, P < 0.0001). Conclusions: Flapless-placed 5 mm long implants achieved similar results as 11.5 mm long implants when supporting immediately loaded cross-arch prostheses both in maxillae and mandibles up to 5 years after loading. These results must be confirmed by other trials, and 10 years post-loading data is necessary before making reliable recommendations. Conflict of interest statement: This study was completely self-financed and no financial support has been sought or obtained, not even in the form of free materials.
2018
Edentulous jaw
Flapless implant placement
Immediate loading
Short dental implants
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/149917
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 17
social impact