Purpose: To evaluate whether 6 mm long × 4 mm wide dental implants could be an alternative to implants of at least 10 mm long placed in bone augmented with bone substitutes in posterior atrophic jaws. Materials and methods: A total of 20 patients with bilateral atrophic mandibles, and 20 patients with bilateral atrophic maxillae, having 5 mm to 7 mm of bone height below the maxillary sinus or 6 mm to 8 mm above the mandibular canal, had their side of the jaws randomly allocated according to a split-mouth design. They were allocated to receive one to three 6 mm long × 4 mm wide implants, or implants of at least 10 mm long in augmented bone by two different surgeons at different centres. Mandibles were vertically augmented with interpositional equine bone blocks and resorbable barriers, and implants were placed 3 months later. Maxillary sinuses were augmented with particulated porcine bone via a lateral window and implants were placed simultaneously. After 4 months, all implants were submerged and loaded with provisional prostheses. Four months later, definitive prostheses were delivered. Outcome measures were prosthesis and implant failures, any complication and radiographic peri-implant marginal bone level changes. Results: Five patients (three treated in mandibles and two in maxillae) dropped out before the 3-year post-loading follow-up. Two short maxillary implants affected by peri-implantitis failed together with their prosthesis vs three mandibular prostheses that could not be placed on implants at least 10 mm long due to graft failures; one was associated with the loss of three implants because of infection. There were no statistically significant differences in implant (difference in proportions = 0.000; 95% CI: -0.140 to 0.140; P = 1.000) and prosthesis failures (difference in proportions = 0.057; 95% CI: -0.094 to 0.216; P = 0.625). In total, 18 complications occurred in 13 patients at augmented sites vs four complications in three patients with 6 mm long implants. Significantly more complications occurred at grafted sites in mandibles (difference in proportions = 0.353; 95% CI: 0.005 to 0.616; P = 0.031), but not in maxillae (difference in proportions = 0.222; 95% CI: -0.071 to 0.486; P = 0.219). In mandibles, patients with 6 mm long implants lost an average of 1.25 mm of periimplant bone at 3 years vs 1.54 mm in patients with implants of at least 10 mm long. The difference was statistically significant (mean difference = 0.29 mm; 95% CI: 0.08 to 0.51 mm; P = 0.010). In maxillas, patients with 6 mm-long implants lost an average of 1.28 mm of peri-implant bone at 3 years vs 1.50 mm in patients with implants of at least 10 mm long. The difference was statistically significant (mean difference = 0.22 mm; 95% CI: 0.08 to 0.35 mm; P = 0.003). Conclusions: Results at 3 years after loading indicate that 6 mm long implants with a conventional diameter of 4 mm achieved similar, if not better, results than longer implants placed in augmented bone. Short implants might be a preferable choice to bone augmentation, especially in posterior mandibles, since the treatment is faster, cheaper and associated with less morbidity. However, data obtained 5 to 10 years after loading are necessary before making reliable recommendations. Conflict of interest statement: Tecnoss and Southern Implants partially supported this trial and donated biomaterials, implants and prosthetic components used in this study. However, the data belonged to the authors and by no means did the manufacturers interfere with the conduct of the trial or the publication of its results.

Posterior atrophic jaws rehabilitated with prostheses supported by 6 mm long × 4 mm wide implants or by longer implants in augmented bone. 3-year post-loading results from a randomised controlled trial / Felice, P.; Barausse, C.; Pistilli, V.; Piattelli, M.; Ippolito, D. R.; Esposito, M.. - In: EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY. - ISSN 1756-2406. - 11:2(2018), pp. 175-187.

Posterior atrophic jaws rehabilitated with prostheses supported by 6 mm long × 4 mm wide implants or by longer implants in augmented bone. 3-year post-loading results from a randomised controlled trial

Esposito M.
Ultimo
2018-01-01

Abstract

Purpose: To evaluate whether 6 mm long × 4 mm wide dental implants could be an alternative to implants of at least 10 mm long placed in bone augmented with bone substitutes in posterior atrophic jaws. Materials and methods: A total of 20 patients with bilateral atrophic mandibles, and 20 patients with bilateral atrophic maxillae, having 5 mm to 7 mm of bone height below the maxillary sinus or 6 mm to 8 mm above the mandibular canal, had their side of the jaws randomly allocated according to a split-mouth design. They were allocated to receive one to three 6 mm long × 4 mm wide implants, or implants of at least 10 mm long in augmented bone by two different surgeons at different centres. Mandibles were vertically augmented with interpositional equine bone blocks and resorbable barriers, and implants were placed 3 months later. Maxillary sinuses were augmented with particulated porcine bone via a lateral window and implants were placed simultaneously. After 4 months, all implants were submerged and loaded with provisional prostheses. Four months later, definitive prostheses were delivered. Outcome measures were prosthesis and implant failures, any complication and radiographic peri-implant marginal bone level changes. Results: Five patients (three treated in mandibles and two in maxillae) dropped out before the 3-year post-loading follow-up. Two short maxillary implants affected by peri-implantitis failed together with their prosthesis vs three mandibular prostheses that could not be placed on implants at least 10 mm long due to graft failures; one was associated with the loss of three implants because of infection. There were no statistically significant differences in implant (difference in proportions = 0.000; 95% CI: -0.140 to 0.140; P = 1.000) and prosthesis failures (difference in proportions = 0.057; 95% CI: -0.094 to 0.216; P = 0.625). In total, 18 complications occurred in 13 patients at augmented sites vs four complications in three patients with 6 mm long implants. Significantly more complications occurred at grafted sites in mandibles (difference in proportions = 0.353; 95% CI: 0.005 to 0.616; P = 0.031), but not in maxillae (difference in proportions = 0.222; 95% CI: -0.071 to 0.486; P = 0.219). In mandibles, patients with 6 mm long implants lost an average of 1.25 mm of periimplant bone at 3 years vs 1.54 mm in patients with implants of at least 10 mm long. The difference was statistically significant (mean difference = 0.29 mm; 95% CI: 0.08 to 0.51 mm; P = 0.010). In maxillas, patients with 6 mm-long implants lost an average of 1.28 mm of peri-implant bone at 3 years vs 1.50 mm in patients with implants of at least 10 mm long. The difference was statistically significant (mean difference = 0.22 mm; 95% CI: 0.08 to 0.35 mm; P = 0.003). Conclusions: Results at 3 years after loading indicate that 6 mm long implants with a conventional diameter of 4 mm achieved similar, if not better, results than longer implants placed in augmented bone. Short implants might be a preferable choice to bone augmentation, especially in posterior mandibles, since the treatment is faster, cheaper and associated with less morbidity. However, data obtained 5 to 10 years after loading are necessary before making reliable recommendations. Conflict of interest statement: Tecnoss and Southern Implants partially supported this trial and donated biomaterials, implants and prosthetic components used in this study. However, the data belonged to the authors and by no means did the manufacturers interfere with the conduct of the trial or the publication of its results.
2018
Bone substitutes
Inlay graft
Short dental implants
Sinus lift
Vertical augmentation
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/149957
Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 42
  • ???jsp.display-item.citation.isi??? 41
social impact