: Despite the withdrawal of the HeartWare Ventricular Assist Device (HVAD), hundreds of patients are still supported with this continuous-flow pump, and the long-term management of these patients is still under debate. This study aims to analyse 5 years survival and freedom from major adverse events in patients supported by HVAD and HeartMate3 (HM3). From 2010 to 2022, the MIRAMACS Italian Registry enrolled all-comer patients receiving a LVAD support at seven Cardiac Surgery Centres. Out of 447 LVAD implantation, 214 (47.9%) received HM3 and 233 (52.1%) received HVAD. Cox-regression analysis adjusted for major confounders showed an increased risk for mortality (HR 1.5 [1.2-1.9]; p = 0.031), for both ischemic stroke (HR 2.08 [1.06-4.08]; p = 0.033) and haemorrhagic stroke (HR 2.6 [1.3-4.9]; p = 0.005), and for pump thrombosis (HR 25.7 [3.5-188.9]; p < 0.001) in HVAD patients. The propensity-score matching analysis (130 pairs of HVAD vs. HM3) confirmed a significantly lower 5 years survival (81.25% vs. 64.1%; p 0.02), freedom from haemorrhagic stroke (90.5% vs. 70.1%; p < 0.001) and from pump thrombosis (98.5% vs. 74.7%; p < 0.001) in HVAD cohort. Although similar perioperative outcome, patients implanted with HVAD developed a higher risk for mortality, haemorrhagic stroke and thrombosis during 5 years of follow-up compared to HM3 patients.

Five-Year Outcome After Continuous Flow LVAD With Full-Magnetic (HeartMate 3) Versus Hybrid Levitation System (HeartWare): A Propensity-Score Matched Study From an All-Comers Multicentre Registry / Francica, A., Loforte, A., Attisani, M., Maiani, M., Iacovoni, A., Nisi, T., Comisso, M., Terzi, A., De Bonis, M., Vendramin, I., Boffini, M., Musumeci, F., Luciani, G.B., Rinaldi, M., Pacini, D., Onorati, F.. - In: TRANSPLANT INTERNATIONAL. - ISSN 1432-2277. - 36:(2023), p. 11675. [10.3389/ti.2023.11675]

Five-Year Outcome After Continuous Flow LVAD With Full-Magnetic (HeartMate 3) Versus Hybrid Levitation System (HeartWare): A Propensity-Score Matched Study From an All-Comers Multicentre Registry

De Bonis, Michele;
2023-01-01

Abstract

: Despite the withdrawal of the HeartWare Ventricular Assist Device (HVAD), hundreds of patients are still supported with this continuous-flow pump, and the long-term management of these patients is still under debate. This study aims to analyse 5 years survival and freedom from major adverse events in patients supported by HVAD and HeartMate3 (HM3). From 2010 to 2022, the MIRAMACS Italian Registry enrolled all-comer patients receiving a LVAD support at seven Cardiac Surgery Centres. Out of 447 LVAD implantation, 214 (47.9%) received HM3 and 233 (52.1%) received HVAD. Cox-regression analysis adjusted for major confounders showed an increased risk for mortality (HR 1.5 [1.2-1.9]; p = 0.031), for both ischemic stroke (HR 2.08 [1.06-4.08]; p = 0.033) and haemorrhagic stroke (HR 2.6 [1.3-4.9]; p = 0.005), and for pump thrombosis (HR 25.7 [3.5-188.9]; p < 0.001) in HVAD patients. The propensity-score matching analysis (130 pairs of HVAD vs. HM3) confirmed a significantly lower 5 years survival (81.25% vs. 64.1%; p 0.02), freedom from haemorrhagic stroke (90.5% vs. 70.1%; p < 0.001) and from pump thrombosis (98.5% vs. 74.7%; p < 0.001) in HVAD cohort. Although similar perioperative outcome, patients implanted with HVAD developed a higher risk for mortality, haemorrhagic stroke and thrombosis during 5 years of follow-up compared to HM3 patients.
2023
Inglese
36
11675
Pubblicato
https://www.scopus.com/record/display.uri?eid=2-s2.0-85171349341&origin=inward&txGid=89c98a6533a81508a31bec3bb165152d
Esperti anonimi
Internazionale
Goal 3: Good health and well-being
HeartMate3
HeartWare
continuous-flow LVAD
full-magnetic levitation pump
hybrid levitation system pump
No
Five-Year Outcome After Continuous Flow LVAD With Full-Magnetic (HeartMate 3) Versus Hybrid Levitation System (HeartWare): A Propensity-Score Matched Study From an All-Comers Multicentre Registry / Francica, A., Loforte, A., Attisani, M., Maiani, M., Iacovoni, A., Nisi, T., Comisso, M., Terzi, A., De Bonis, M., Vendramin, I., Boffini, M., Musumeci, F., Luciani, G.B., Rinaldi, M., Pacini, D., Onorati, F.. - In: TRANSPLANT INTERNATIONAL. - ISSN 1432-2277. - 36:(2023), p. 11675. [10.3389/ti.2023.11675]
open
16
info:eu-repo/semantics/article
262
Francica, Alessandra; Loforte, Antonio; Attisani, Matteo; Maiani, Massimo; Iacovoni, Attilio; Nisi, Teodora; Comisso, Marina; Terzi, Amedeo; De Bonis,...espandi
1 Contributo su Rivista::1.1 Articolo in rivista
File in questo prodotto:
File Dimensione Formato  
ti-36-11675.pdf

accesso aperto

Tipologia: PDF editoriale (versione pubblicata dall'editore)
Licenza: Creative commons
Dimensione 2.1 MB
Formato Adobe PDF
2.1 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/151396
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 8
social impact