Background: Diabetic patients are at higher risk of recurrent adverse events following percutaneous coronary intervention (PCI) than the nondiabetics. Despite the introduction of new generation drug-eluting stents, their efficacy in the diabetics is still limited. Aims: To evaluate the efficacy of the Abluminus DES+ biodegradable polymer sirolimus-eluting stent in reducing neointimal hyperplasia in diabetic patients, compared to a durable polymer everolimus-eluting stent (DP-EES). Methods: A total of 131 patients with diabetes and coronary artery disease were enrolled in six Italian centers and randomized in a 2:1 fashion to PCI with Abluminus DES+ or DP-EES: 85 were assigned to Abluminus DES+ and 46 to DP-EES. The primary endpoint was optimal coherence tomography (OCT)-derived neointimal volume at 9–12 months. Secondary endpoints included OCT-derived neointimal area, neointimal volume obstruction and adverse clinical events. Results: The primary endpoint, neointimal volume, did not differ between Abluminus DES+ and DP-EES (29.11 ± 18.90 mm3 vs. 25.48 ± 17.04 mm3, p = 0.40) at 9–12-month follow-up. This finding remained consistent after weighing for the sum of stents lengths (1.14 ± 0.68 mm3 vs. 0.99 ± 0.74 mm3 for Abluminus DES+ and DP-EES, respectively, p = 0.38). Similarly, other OCT-derived and clinical secondary endpoints did not significantly differ between the two groups. Rate of target lesion failure was high in both groups (21.2% for Abluminus DES+ and 19.6% for DP-EES). Conclusions: This preliminary study failed to demonstrate the superiority of the Abluminus DES+ over the DP-EES in diabetic patients in terms of neointimal proliferation.
Randomized clinical trial of abluminus DES+ sirolimus-eluting stent versus everolimus-eluting DES for percutaneous coronary intervention in patients with diabetes mellitus: An optical coherence tomography study / Maurina, M.; Chiarito, M.; Leone, P. P.; Testa, L.; Montorfano, M.; Reimers, B.; Esposito, G.; Monti, F.; Ferrario, M.; Latib, A.; Colombo, A.. - In: CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS. - ISSN 1522-1946. - 102:6(2023), pp. 1020-1033. [10.1002/ccd.30853]
Randomized clinical trial of abluminus DES+ sirolimus-eluting stent versus everolimus-eluting DES for percutaneous coronary intervention in patients with diabetes mellitus: An optical coherence tomography study
Testa L.;Montorfano M.;
2023-01-01
Abstract
Background: Diabetic patients are at higher risk of recurrent adverse events following percutaneous coronary intervention (PCI) than the nondiabetics. Despite the introduction of new generation drug-eluting stents, their efficacy in the diabetics is still limited. Aims: To evaluate the efficacy of the Abluminus DES+ biodegradable polymer sirolimus-eluting stent in reducing neointimal hyperplasia in diabetic patients, compared to a durable polymer everolimus-eluting stent (DP-EES). Methods: A total of 131 patients with diabetes and coronary artery disease were enrolled in six Italian centers and randomized in a 2:1 fashion to PCI with Abluminus DES+ or DP-EES: 85 were assigned to Abluminus DES+ and 46 to DP-EES. The primary endpoint was optimal coherence tomography (OCT)-derived neointimal volume at 9–12 months. Secondary endpoints included OCT-derived neointimal area, neointimal volume obstruction and adverse clinical events. Results: The primary endpoint, neointimal volume, did not differ between Abluminus DES+ and DP-EES (29.11 ± 18.90 mm3 vs. 25.48 ± 17.04 mm3, p = 0.40) at 9–12-month follow-up. This finding remained consistent after weighing for the sum of stents lengths (1.14 ± 0.68 mm3 vs. 0.99 ± 0.74 mm3 for Abluminus DES+ and DP-EES, respectively, p = 0.38). Similarly, other OCT-derived and clinical secondary endpoints did not significantly differ between the two groups. Rate of target lesion failure was high in both groups (21.2% for Abluminus DES+ and 19.6% for DP-EES). Conclusions: This preliminary study failed to demonstrate the superiority of the Abluminus DES+ over the DP-EES in diabetic patients in terms of neointimal proliferation.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.