: Background: Rotary Ni-Ti files are susceptible to sudden intra-canal separation due to cyclic fatigue stress, particularly in curved canals. To increase resistance to cyclic fatigue, new heat-treated files have been introduced. This study aimed to compare the performance of four heat-treated Ni-Ti files in two simulated curved root canals by evaluating the effect of the alloy, rotation speed, and diameter of the files on their resistance to cyclic fatigue. Methods: The Ni-Ti files included in the study were the ProTaper Gold® (Dentsply Sirona) F2, ProTaper Ultimate® (Dentsply Sirona) F2, FQ® (Komet) 25.06, and Blueshaper® (Zarc4Endo) Z4 25.06. Two groups of 30 files were selected for each system and were tested in two simulated canals milled in a specific metal template. One group was tested in a 60° curved canal and the other in a 90° curved canal. Results: In the 60° simulated canal, there were no instrument fractures within the 15 min time limit. In the 90° simulated canal, the Blueshaper Z4 demonstrated a lower resistance to cyclic fatigue, while FQ 25.06 showed statistically higher fatigue resistance based on both the Kruskal-Wallis and Games-Howell tests (p < 0.05). Conclusions: No differences were found between files when tested in a 60° curved canal for up to 15 min. However, in a 90° canal, the FQ® files showed significantly higher resistance to cyclic fatigue, especially compared to the Blueshaper® Z4. The ProTaper Ultimate and ProTaper Gold produced intermediate results, with the ProTaper Ultimate F2 slightly outperforming the ProTaper Gold F2.

Cyclic Fatigue Resistance of Four Heat-Treated Nickel-Titanium Files in Severely Curved Simulated Canals: An In Vitro Study / Greco, Katia; Paolone, Gaetano; Cicero, Giuseppe; Tetè, Giulia; Cantile, Nicola; Sberna, Maria Teresa; Saladino, Teresa; Gherlone, Enrico Felice; Cantatore, Giuseppe. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 13:19(2024). [10.3390/jcm13195739]

Cyclic Fatigue Resistance of Four Heat-Treated Nickel-Titanium Files in Severely Curved Simulated Canals: An In Vitro Study

Paolone, Gaetano
Secondo
;
Tetè, Giulia
;
Cantile, Nicola
;
Gherlone, Enrico Felice
;
Cantatore, Giuseppe
Ultimo
Writing – Review & Editing
2024-01-01

Abstract

: Background: Rotary Ni-Ti files are susceptible to sudden intra-canal separation due to cyclic fatigue stress, particularly in curved canals. To increase resistance to cyclic fatigue, new heat-treated files have been introduced. This study aimed to compare the performance of four heat-treated Ni-Ti files in two simulated curved root canals by evaluating the effect of the alloy, rotation speed, and diameter of the files on their resistance to cyclic fatigue. Methods: The Ni-Ti files included in the study were the ProTaper Gold® (Dentsply Sirona) F2, ProTaper Ultimate® (Dentsply Sirona) F2, FQ® (Komet) 25.06, and Blueshaper® (Zarc4Endo) Z4 25.06. Two groups of 30 files were selected for each system and were tested in two simulated canals milled in a specific metal template. One group was tested in a 60° curved canal and the other in a 90° curved canal. Results: In the 60° simulated canal, there were no instrument fractures within the 15 min time limit. In the 90° simulated canal, the Blueshaper Z4 demonstrated a lower resistance to cyclic fatigue, while FQ 25.06 showed statistically higher fatigue resistance based on both the Kruskal-Wallis and Games-Howell tests (p < 0.05). Conclusions: No differences were found between files when tested in a 60° curved canal for up to 15 min. However, in a 90° canal, the FQ® files showed significantly higher resistance to cyclic fatigue, especially compared to the Blueshaper® Z4. The ProTaper Ultimate and ProTaper Gold produced intermediate results, with the ProTaper Ultimate F2 slightly outperforming the ProTaper Gold F2.
2024
cyclic fatigue
heattreated NiTi alloy
martensitic NiTi endodontic instruments
rotary endodontic files
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/172416
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact