: Background: Rotary Ni-Ti files are susceptible to sudden intra-canal separation due to cyclic fatigue stress, particularly in curved canals. To increase resistance to cyclic fatigue, new heat-treated files have been introduced. This study aimed to compare the performance of four heat-treated Ni-Ti files in two simulated curved root canals by evaluating the effect of the alloy, rotation speed, and diameter of the files on their resistance to cyclic fatigue. Methods: The Ni-Ti files included in the study were the ProTaper Gold® (Dentsply Sirona) F2, ProTaper Ultimate® (Dentsply Sirona) F2, FQ® (Komet) 25.06, and Blueshaper® (Zarc4Endo) Z4 25.06. Two groups of 30 files were selected for each system and were tested in two simulated canals milled in a specific metal template. One group was tested in a 60° curved canal and the other in a 90° curved canal. Results: In the 60° simulated canal, there were no instrument fractures within the 15 min time limit. In the 90° simulated canal, the Blueshaper Z4 demonstrated a lower resistance to cyclic fatigue, while FQ 25.06 showed statistically higher fatigue resistance based on both the Kruskal-Wallis and Games-Howell tests (p < 0.05). Conclusions: No differences were found between files when tested in a 60° curved canal for up to 15 min. However, in a 90° canal, the FQ® files showed significantly higher resistance to cyclic fatigue, especially compared to the Blueshaper® Z4. The ProTaper Ultimate and ProTaper Gold produced intermediate results, with the ProTaper Ultimate F2 slightly outperforming the ProTaper Gold F2.

Cyclic Fatigue Resistance of Four Heat-Treated Nickel-Titanium Files in Severely Curved Simulated Canals: An In Vitro Study / Greco, Katia; Paolone, Gaetano; Cicero, Giuseppe; Tetè, Giulia; Cantile, Nicola; Sberna, Maria Teresa; Saladino, Teresa; Gherlone, Enrico Felice; Cantatore, Giuseppe. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 13:19(2024). [10.3390/jcm13195739]

Cyclic Fatigue Resistance of Four Heat-Treated Nickel-Titanium Files in Severely Curved Simulated Canals: An In Vitro Study

Paolone, Gaetano
Secondo
;
Tetè, Giulia
;
Cantile, Nicola
;
Gherlone, Enrico Felice
;
Cantatore, Giuseppe
Ultimo
Writing – Review & Editing
2024-01-01

Abstract

: Background: Rotary Ni-Ti files are susceptible to sudden intra-canal separation due to cyclic fatigue stress, particularly in curved canals. To increase resistance to cyclic fatigue, new heat-treated files have been introduced. This study aimed to compare the performance of four heat-treated Ni-Ti files in two simulated curved root canals by evaluating the effect of the alloy, rotation speed, and diameter of the files on their resistance to cyclic fatigue. Methods: The Ni-Ti files included in the study were the ProTaper Gold® (Dentsply Sirona) F2, ProTaper Ultimate® (Dentsply Sirona) F2, FQ® (Komet) 25.06, and Blueshaper® (Zarc4Endo) Z4 25.06. Two groups of 30 files were selected for each system and were tested in two simulated canals milled in a specific metal template. One group was tested in a 60° curved canal and the other in a 90° curved canal. Results: In the 60° simulated canal, there were no instrument fractures within the 15 min time limit. In the 90° simulated canal, the Blueshaper Z4 demonstrated a lower resistance to cyclic fatigue, while FQ 25.06 showed statistically higher fatigue resistance based on both the Kruskal-Wallis and Games-Howell tests (p < 0.05). Conclusions: No differences were found between files when tested in a 60° curved canal for up to 15 min. However, in a 90° canal, the FQ® files showed significantly higher resistance to cyclic fatigue, especially compared to the Blueshaper® Z4. The ProTaper Ultimate and ProTaper Gold produced intermediate results, with the ProTaper Ultimate F2 slightly outperforming the ProTaper Gold F2.
2024
Inglese
MDPI
13
19
11
Pubblicato
https://www.mdpi.com/2077-0383/13/19/5739
Esperti anonimi
Internazionale
Goal 3: Good health and well-being
cyclic fatigue
heattreated NiTi alloy
martensitic NiTi endodontic instruments
rotary endodontic files
No
UNISR.MED
Cyclic Fatigue Resistance of Four Heat-Treated Nickel-Titanium Files in Severely Curved Simulated Canals: An In Vitro Study / Greco, Katia; Paolone, Gaetano; Cicero, Giuseppe; Tetè, Giulia; Cantile, Nicola; Sberna, Maria Teresa; Saladino, Teresa; Gherlone, Enrico Felice; Cantatore, Giuseppe. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 13:19(2024). [10.3390/jcm13195739]
open
9
info:eu-repo/semantics/article
262
Greco, Katia; Paolone, Gaetano; Cicero, Giuseppe; Tetè, Giulia; Cantile, Nicola; Sberna, Maria Teresa; Saladino, Teresa; Gherlone, Enrico Felice; Cant...espandi
1 Contributo su Rivista::1.1 Articolo in rivista
File in questo prodotto:
File Dimensione Formato  
jcm-13-05739-with-cover.pdf

accesso aperto

Tipologia: PDF editoriale (versione pubblicata dall'editore)
Licenza: Creative commons
Dimensione 1.02 MB
Formato Adobe PDF
1.02 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/172416
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 4
social impact