Aims: Continuous glucose monitoring (CGM) can improve glucometrics in children with type 1 diabetes (T1D), and its efficacy is positively related to glucose sensor use for at least 60% of the time. We therefore investigated the relationship between CGM satisfaction as assessed by a robust questionnaire and glucose control in pediatric T1D patients. Methods: This was a cross-sectional study of children and adolescents with T1D using CGM. The CGM Satisfaction (CGM-SAT) questionnaire was administered to patients and demographic, clinical, and glucometrics data were recorded. Results: Two hundred and ten consecutively enrolled patients attending 14 Italian pediatric diabetes clinics completed the CGM-SAT questionnaire. CGM-SAT scores were not associated with age, gender, annual HbA1c, % of time with an active sensor, time above range (TAR), time below range (TBR), and coefficient of variation (CV). However, CGM satisfaction was positively correlated with time in range (TIR, p < 0.05) and negatively correlated with glycemia risk index (GRI, p < 0.05). Conclusions: CGM seems to have a positive effect on glucose control in patients with T1D. CGM satisfaction is therefore an important patient-reported outcome to assess and it is associated with increased TIR and reduced GRI.
Satisfaction with continuous glucose monitoring is positively correlated with time in range in children with type 1 diabetes / Marigliano, M.; Pertile, R.; Mozzillo, E.; Troncone, A.; Maffeis, C.; Morotti, E.; Di Candia, F.; Fedi, L.; Iafusco, D.; Zanfardino, A.; Cauvin, V.; Maltoni, G.; Zucchini, S.; Cherubini, V.; Tiberi, V.; Minuto, N.; Bassi, M.; Rabbone, I.; Savastio, S.; Tinti, D.; Tornese, G.; Schiaffini, R.; Passanisi, S.; Lombardo, F.; Bonfanti, R.; Scaramuzza, A.; Franceschi, R.. - In: DIABETES RESEARCH AND CLINICAL PRACTICE. - ISSN 0168-8227. - 204:(2023). [10.1016/j.diabres.2023.110895]
Satisfaction with continuous glucose monitoring is positively correlated with time in range in children with type 1 diabetes
Morotti E.;Bonfanti R.;
2023-01-01
Abstract
Aims: Continuous glucose monitoring (CGM) can improve glucometrics in children with type 1 diabetes (T1D), and its efficacy is positively related to glucose sensor use for at least 60% of the time. We therefore investigated the relationship between CGM satisfaction as assessed by a robust questionnaire and glucose control in pediatric T1D patients. Methods: This was a cross-sectional study of children and adolescents with T1D using CGM. The CGM Satisfaction (CGM-SAT) questionnaire was administered to patients and demographic, clinical, and glucometrics data were recorded. Results: Two hundred and ten consecutively enrolled patients attending 14 Italian pediatric diabetes clinics completed the CGM-SAT questionnaire. CGM-SAT scores were not associated with age, gender, annual HbA1c, % of time with an active sensor, time above range (TAR), time below range (TBR), and coefficient of variation (CV). However, CGM satisfaction was positively correlated with time in range (TIR, p < 0.05) and negatively correlated with glycemia risk index (GRI, p < 0.05). Conclusions: CGM seems to have a positive effect on glucose control in patients with T1D. CGM satisfaction is therefore an important patient-reported outcome to assess and it is associated with increased TIR and reduced GRI.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.