In chronic lymphocytic leukemia (CLL) the level of minimal residual disease (MRD) after therapy is an independent predictor of outcome. Given the increasing number of new agents being explored for CLL therapy, using MRD as surrogate could greatly reduce the time necessary to assess their efficacy. In this ERIC project we have identified and validated a flow-cytometric approach to reliably quantitate CLL cells to the level of 0.0010% (10-5). The assay comprises a core panel of six markers (i.e. CD19, CD20, CD5, CD43, CD79b, and CD81) with a component specification independent of instrument and reagents, which can be locally re-validated using normal peripheral blood. This method is directly comparable to previous ERIC-designed assays and also provides a backbone for investigation of new markers. A parallel analysis of high-throughput sequencing using the ClonoSEQ assay showed good concordance with flow cytometry results at the 0.010% (10-4) level, the MRD threshold defined in the 2008 IWCLL guidelines, but it also provides good linearity to a detection limit of 1 in a million (10-6). The combination of both technologies would permit a highly sensitive approach to MRD detection while providing a reproducible and broadly accessible method to quantify residual disease and optimize treatment in CLL.

A complementary role of multiparameter flow-cytometry and high-throughput sequencing for minimal residual disease (MRD) detection in chronic lymphocytic leukemia (CLL): An european research initiative on CLL (ERIC) study

GHIA , PAOLO PROSPERO
2016-01-01

Abstract

In chronic lymphocytic leukemia (CLL) the level of minimal residual disease (MRD) after therapy is an independent predictor of outcome. Given the increasing number of new agents being explored for CLL therapy, using MRD as surrogate could greatly reduce the time necessary to assess their efficacy. In this ERIC project we have identified and validated a flow-cytometric approach to reliably quantitate CLL cells to the level of 0.0010% (10-5). The assay comprises a core panel of six markers (i.e. CD19, CD20, CD5, CD43, CD79b, and CD81) with a component specification independent of instrument and reagents, which can be locally re-validated using normal peripheral blood. This method is directly comparable to previous ERIC-designed assays and also provides a backbone for investigation of new markers. A parallel analysis of high-throughput sequencing using the ClonoSEQ assay showed good concordance with flow cytometry results at the 0.010% (10-4) level, the MRD threshold defined in the 2008 IWCLL guidelines, but it also provides good linearity to a detection limit of 1 in a million (10-6). The combination of both technologies would permit a highly sensitive approach to MRD detection while providing a reproducible and broadly accessible method to quantify residual disease and optimize treatment in CLL.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/17549
Citazioni
  • ???jsp.display-item.citation.pmc??? 63
  • Scopus 186
  • ???jsp.display-item.citation.isi??? 165
social impact