Background: Recently, several devices exploiting the near-infrared autofluorescence (NIR-AF) of parathyroid glands (PGs) have been developed. Nevertheless, their impact on both preserving PGs from inadvertent surgical dissection and on post-surgical hypoparathyroidism (hypoPTH) is controversial. Methods: A retrospective study of 845 patients undergoing thyroid surgery in 2 academic tertiary centres was conducted. In 291 patients, a NIR-AF device was used during surgery to identify PGs. The characteristics of the cohort were examined. The number of PGs identified during surgery, missed PGs, auto-transplants, inadvertent parathyroidectomies, as well as the occurrence of transient and permanent hypoPTH, were analysed. Results: The use of NIR-AF device resulted in a higher identification of PGs (92% versus 88%, p = 0.0008), and a significant reduction in the number of PGs inadvertently removed and detected on histopathological examination (4.7% versus 6.5%, p = 0.045). An increase in PG auto-transplantations was observed in the NIR-AF + group (10.4% versus 3.5%, p < 0.0001). The use of NIRAF did not significantly impact the occurrence of either transient or permanent hypoPTH. Conclusion: Intraoperative NIR-AF detection is a promising technology to reduce incidental parathyroidectomies in thyroid surgery. The impact of this technology on the occurrence of post-surgical hypoPTH needs to be furtherly investigated.

Will the autofluorescence take over inadvertent parathyroidectomy? Results from a multicentre cohort study / Barbieri, D.; Indelicato, P.; De Leo, S.; Moneta, C.; Coccia, S.; Gazzano, G.; Giordano, L.; Luce, F. L.; Canta, D.; Fugazzola, L.; Bussi, M.; Dionigi, G.; Trevisan, M.. - In: UPDATES IN SURGERY. - ISSN 2038-131X. - (2025). [10.1007/s13304-025-02083-7]

Will the autofluorescence take over inadvertent parathyroidectomy? Results from a multicentre cohort study

Indelicato P.;Giordano L.;Canta D.;Bussi M.;
2025-01-01

Abstract

Background: Recently, several devices exploiting the near-infrared autofluorescence (NIR-AF) of parathyroid glands (PGs) have been developed. Nevertheless, their impact on both preserving PGs from inadvertent surgical dissection and on post-surgical hypoparathyroidism (hypoPTH) is controversial. Methods: A retrospective study of 845 patients undergoing thyroid surgery in 2 academic tertiary centres was conducted. In 291 patients, a NIR-AF device was used during surgery to identify PGs. The characteristics of the cohort were examined. The number of PGs identified during surgery, missed PGs, auto-transplants, inadvertent parathyroidectomies, as well as the occurrence of transient and permanent hypoPTH, were analysed. Results: The use of NIR-AF device resulted in a higher identification of PGs (92% versus 88%, p = 0.0008), and a significant reduction in the number of PGs inadvertently removed and detected on histopathological examination (4.7% versus 6.5%, p = 0.045). An increase in PG auto-transplantations was observed in the NIR-AF + group (10.4% versus 3.5%, p < 0.0001). The use of NIRAF did not significantly impact the occurrence of either transient or permanent hypoPTH. Conclusion: Intraoperative NIR-AF detection is a promising technology to reduce incidental parathyroidectomies in thyroid surgery. The impact of this technology on the occurrence of post-surgical hypoPTH needs to be furtherly investigated.
2025
Autofluorescence
Hypocalcemia
Near-infrared autofluorescence (NIRAF)
Near-infrared fluorescence imaging (NIFI)
Thyroid surgery
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/179021
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact