Purpose: This in vitro study aimed to compare the accuracy of dental implant placement in partially edentulous maxillary models using a mixed reality-based dynamic navigation (MR-DN) system to conventional static computer-assisted implant surgery (s-CAIS) and a freehand (FH) method. Methods: Forty-five partially edentulous models (with teeth missing in positions #15, #16 and #25) were assigned to three groups (15 per group). The same experienced operator performed the model surgeries using an MR-DN system (group 1), s-CAIS (group 2) and FH (group 3). In total, 135 dental implants were placed (45 per group). The primary outcomes were the linear coronal deviation (entry error; En), apical deviation (apex error; Ap), XY and Z deviations, and angular deviation (An) between the planned and actual (post-surgery) position of the implants in the models. These deviations were computed as the distances between the stereolithographic (STL) files for the planned implants and placed implants captured with an intraoral scanner. Results: Across the three implant sites, the MR-DN system was significantly more accurate than the FH method (in XY, Z, En, Ap and An) and s-CAIS (in Z, Ap and An), respectively. However, S-CAIS was more accurate than MR-DN in XY, and no difference was found between MR-DN and s-CAIS in En. Conclusions: Within the limits of this study (in vitro design, only partially edentulous models), implant placement accuracy with MR-DN was superior to that of FH and similar to that of s-CAIS. Statement of Clinical Relevance: In vitro, MR-DN showed greater accuracy in implant positioning than FH, and similar accuracy to s-CAIS: it could, therefore, represent a new option for the surgeon. However, clinical studies are needed to determine the feasibility of MR-DN.

Accuracy of implant placement using a mixed reality-based dynamic navigation system versus static computer-assisted and freehand surgery: An in Vitro study / Shusterman, A.; Nashef, R.; Tecco, S.; Mangano, C.; Lerner, H.; Mangano, F. G.. - In: JOURNAL OF DENTISTRY. - ISSN 0300-5712. - 146:(2024). [10.1016/j.jdent.2024.105052]

Accuracy of implant placement using a mixed reality-based dynamic navigation system versus static computer-assisted and freehand surgery: An in Vitro study

Tecco S.;
2024-01-01

Abstract

Purpose: This in vitro study aimed to compare the accuracy of dental implant placement in partially edentulous maxillary models using a mixed reality-based dynamic navigation (MR-DN) system to conventional static computer-assisted implant surgery (s-CAIS) and a freehand (FH) method. Methods: Forty-five partially edentulous models (with teeth missing in positions #15, #16 and #25) were assigned to three groups (15 per group). The same experienced operator performed the model surgeries using an MR-DN system (group 1), s-CAIS (group 2) and FH (group 3). In total, 135 dental implants were placed (45 per group). The primary outcomes were the linear coronal deviation (entry error; En), apical deviation (apex error; Ap), XY and Z deviations, and angular deviation (An) between the planned and actual (post-surgery) position of the implants in the models. These deviations were computed as the distances between the stereolithographic (STL) files for the planned implants and placed implants captured with an intraoral scanner. Results: Across the three implant sites, the MR-DN system was significantly more accurate than the FH method (in XY, Z, En, Ap and An) and s-CAIS (in Z, Ap and An), respectively. However, S-CAIS was more accurate than MR-DN in XY, and no difference was found between MR-DN and s-CAIS in En. Conclusions: Within the limits of this study (in vitro design, only partially edentulous models), implant placement accuracy with MR-DN was superior to that of FH and similar to that of s-CAIS. Statement of Clinical Relevance: In vitro, MR-DN showed greater accuracy in implant positioning than FH, and similar accuracy to s-CAIS: it could, therefore, represent a new option for the surgeon. However, clinical studies are needed to determine the feasibility of MR-DN.
2024
Freehand implant placement
Guided implant surgery
Holograms, accuracy
Mixed reality
Static guided implant surgery
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0300571224002215-main.pdf

solo gestori archivio

Tipologia: PDF editoriale (versione pubblicata dall'editore)
Licenza: Tutti i diritti riservati
Dimensione 13.94 MB
Formato Adobe PDF
13.94 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/183739
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 9
social impact