BACKGROUND: Hypotensive events and drops in systolic blood pressure (SBP-drop) are frequent in patients hospitalized with acute heart failure. We investigated whether SBP-drops are associated with outcomes in patients treated with serelaxin.METHODS: Patient-level retrospective analyses of 4 prospective trials investigating serelaxin in acute heart failure. Main inclusion criteria were SBP 125 to 180 mm Hg, pulmonary congestion, and elevated NT-proBNP (N-terminal pro-B-type natriuretic peptide). SBP-drops were prospectively defined as SBP<100 mm Hg, or, if SBP remained >100 mm Hg, a drop from baseline of 40 mm Hg from baseline. Outcomes were a short-term composite outcome (worsening heart failure, hospital readmission for heart failure or all-cause mortality through 14 days) and 180-day mortality.RESULTS: Overall, 2559/11226 (23%) patients had an SBP-drop. SBP-drop, versus no SBP-drop, was associated with a worse outcome: cumulative incidence of 180-day mortality (11% versus 9%, hazard ratio [HR]. 1.21 [95% CI, 1.05-1.39]; P=0.009) and the short-term outcome (11% versus 9%, HR, 1.29 [95% CI, 1.13-1.49]; P<0.001). Of the 2 SBP-drop components, an SBP<100 mmHg was associated with the worst outcome compared with a 40 mmHg drop: short-term outcome (11% versus 10%) and H Rs of 1.32 (95% CI, 1.13-1.55; P=0.0005) and 1.22 (95% CI, 0.97-1.56; P=0.09), for each component respectively, with a Pvalue for interaction of 0.05. SBP-drops were associated with a worse short-term outcome in the placebo group (HR, 1.46 [95% CI, 1.19-1.79]; P=0.0003), but not in the serelaxin-group (HR, 1.18 [95% CI, 0.97-1.42]; P=0.10); P interaction=003.CONCLUSIONS: SBP-drops in patients with acute heart failure and normal to high SBP at admission is associated with worse short- and long-term outcomes especially for SBP<100 mm Hg. However, in patients treated with the intravenous vasodilator serelaxin, SBP-drops seemed less harmful.

Blood Pressure Drops During Hospitalization for Acute Heart Failure Treated With Serelaxin: A Patient-Level Analysis of 4 Randomized Controlled Trials / Grand, Johannes; Miger, Kristina; Sajadieh, Ahmad; Køber, Lars; Torp-Pedersen, Christian; Ertl, Georg; López-Sendón, José; Pietro Maggioni, Aldo; Teerlink, John R; Sato, Naoki; Gimpelewicz, Claudio; Metra, Marco; Holbro, Thomas; Nielsen, Olav W. - In: CIRCULATION. HEART FAILURE. - ISSN 1941-3289. - 15:4(2022), pp. e009199-378. [10.1161/CIRCHEARTFAILURE.121.009199]

Blood Pressure Drops During Hospitalization for Acute Heart Failure Treated With Serelaxin: A Patient-Level Analysis of 4 Randomized Controlled Trials

Metra, Marco;
2022-01-01

Abstract

BACKGROUND: Hypotensive events and drops in systolic blood pressure (SBP-drop) are frequent in patients hospitalized with acute heart failure. We investigated whether SBP-drops are associated with outcomes in patients treated with serelaxin.METHODS: Patient-level retrospective analyses of 4 prospective trials investigating serelaxin in acute heart failure. Main inclusion criteria were SBP 125 to 180 mm Hg, pulmonary congestion, and elevated NT-proBNP (N-terminal pro-B-type natriuretic peptide). SBP-drops were prospectively defined as SBP<100 mm Hg, or, if SBP remained >100 mm Hg, a drop from baseline of 40 mm Hg from baseline. Outcomes were a short-term composite outcome (worsening heart failure, hospital readmission for heart failure or all-cause mortality through 14 days) and 180-day mortality.RESULTS: Overall, 2559/11226 (23%) patients had an SBP-drop. SBP-drop, versus no SBP-drop, was associated with a worse outcome: cumulative incidence of 180-day mortality (11% versus 9%, hazard ratio [HR]. 1.21 [95% CI, 1.05-1.39]; P=0.009) and the short-term outcome (11% versus 9%, HR, 1.29 [95% CI, 1.13-1.49]; P<0.001). Of the 2 SBP-drop components, an SBP<100 mmHg was associated with the worst outcome compared with a 40 mmHg drop: short-term outcome (11% versus 10%) and H Rs of 1.32 (95% CI, 1.13-1.55; P=0.0005) and 1.22 (95% CI, 0.97-1.56; P=0.09), for each component respectively, with a Pvalue for interaction of 0.05. SBP-drops were associated with a worse short-term outcome in the placebo group (HR, 1.46 [95% CI, 1.19-1.79]; P=0.0003), but not in the serelaxin-group (HR, 1.18 [95% CI, 0.97-1.42]; P=0.10); P interaction=003.CONCLUSIONS: SBP-drops in patients with acute heart failure and normal to high SBP at admission is associated with worse short- and long-term outcomes especially for SBP<100 mm Hg. However, in patients treated with the intravenous vasodilator serelaxin, SBP-drops seemed less harmful.
2022
blood pressure
heart failure
hospitalization
hypotension
mortality
Blood Pressure
Hospitalization
Humans
Prospective Studies
Randomized Controlled Trials as Topic
Recombinant Proteins
Retrospective Studies
Treatment Outcome
Vasodilator Agents
Heart Failure
Hypotension
Relaxin
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/193378
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact