Purpose To develop and validate a deep learning model for the segmentation of five retinal biomarkers associated with neovascular age-related macular degeneration (nAMD). Methods 300 optical coherence tomography volumes from subject eyes with nAMD were collected. Images were manually segmented for the presence of five crucial nAMD features: intraretinal fluid, subretinal fluid, subretinal hyperreflective material, drusen/drusenoid pigment epithelium detachment (PED) and neovascular PED. A deep learning architecture based on a U-Net was trained to perform automatic segmentation of these retinal biomarkers and evaluated on the sequestered data. The main outcome measures were receiver operating characteristic curves for detection, summarised using the area under the curves (AUCs) both on a per slice and per volume basis, correlation score, enface topography overlap (reported as two-dimensional (2D) correlation score) and Dice coefficients. Results The model obtained a mean (±SD) AUC of 0.93 (±0.04) per slice and 0.88 (±0.07) per volume for fluid detection. The correlation score (R 2) between automatic and manual segmentation obtained by the model resulted in a mean (±SD) of 0.89 (±0.05). The mean (±SD) 2D correlation score was 0.69 (±0.04). The mean (±SD) Dice score resulted in 0.61 (±0.10). Conclusions We present a fully automated segmentation model for five features related to nAMD that performs at the level of experienced graders. The application of this model will open opportunities for the study of morphological changes and treatment efficacy in real-world settings. Furthermore, it can facilitate structured reporting in the clinic and reduce subjectivity in clinicians' assessments.

Validation of a deep learning model for automatic detection and quantification of five OCT critical retinal features associated with neovascular age-related macular degeneration / Ricardi, F.; Oakley, J.; Russakoff, D.; Boscia, G.; Caselgrandi, P.; Gelormini, F.; Ghilardi, A.; Pintore, G.; Tibaldi, T.; Marolo, P.; Bandello, F.; Reibaldi, M.; Borrelli, E.. - In: BRITISH JOURNAL OF OPHTHALMOLOGY. - ISSN 0007-1161. - 108:10(2024), pp. 1436-1442. [10.1136/bjo-2023-324647]

Validation of a deep learning model for automatic detection and quantification of five OCT critical retinal features associated with neovascular age-related macular degeneration

Bandello F.;Borrelli E.
Ultimo
2024-01-01

Abstract

Purpose To develop and validate a deep learning model for the segmentation of five retinal biomarkers associated with neovascular age-related macular degeneration (nAMD). Methods 300 optical coherence tomography volumes from subject eyes with nAMD were collected. Images were manually segmented for the presence of five crucial nAMD features: intraretinal fluid, subretinal fluid, subretinal hyperreflective material, drusen/drusenoid pigment epithelium detachment (PED) and neovascular PED. A deep learning architecture based on a U-Net was trained to perform automatic segmentation of these retinal biomarkers and evaluated on the sequestered data. The main outcome measures were receiver operating characteristic curves for detection, summarised using the area under the curves (AUCs) both on a per slice and per volume basis, correlation score, enface topography overlap (reported as two-dimensional (2D) correlation score) and Dice coefficients. Results The model obtained a mean (±SD) AUC of 0.93 (±0.04) per slice and 0.88 (±0.07) per volume for fluid detection. The correlation score (R 2) between automatic and manual segmentation obtained by the model resulted in a mean (±SD) of 0.89 (±0.05). The mean (±SD) 2D correlation score was 0.69 (±0.04). The mean (±SD) Dice score resulted in 0.61 (±0.10). Conclusions We present a fully automated segmentation model for five features related to nAMD that performs at the level of experienced graders. The application of this model will open opportunities for the study of morphological changes and treatment efficacy in real-world settings. Furthermore, it can facilitate structured reporting in the clinic and reduce subjectivity in clinicians' assessments.
2024
Inglese
BMJ Publishing Group
108
10
1436
1442
7
Pubblicato
https://bjo.bmj.com/content/108/10/1436
Esperti anonimi
Internazionale
Goal 3: Good health and well-being
Diagnostic tests/Investigation
Imaging
Macula
Neovascularisation
Validation of a deep learning model for automatic detection and quantification of five OCT critical retinal features associated with neovascular age-related macular degeneration / Ricardi, F.; Oakley, J.; Russakoff, D.; Boscia, G.; Caselgrandi, P.; Gelormini, F.; Ghilardi, A.; Pintore, G.; Tibaldi, T.; Marolo, P.; Bandello, F.; Reibaldi, M.; Borrelli, E.. - In: BRITISH JOURNAL OF OPHTHALMOLOGY. - ISSN 0007-1161. - 108:10(2024), pp. 1436-1442. [10.1136/bjo-2023-324647]
none
13
info:eu-repo/semantics/article
262
Ricardi, F.; Oakley, J.; Russakoff, D.; Boscia, G.; Caselgrandi, P.; Gelormini, F.; Ghilardi, A.; Pintore, G.; Tibaldi, T.; Marolo, P.; Bandello, F.; ...espandi
1 Contributo su Rivista::1.1 Articolo in rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/198067
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 9
social impact