Aims The third-generation laser balloon (LB3) is an established ablation device for pulmonary vein isolation (PVI) that allows direct visualization of the anatomical target. Equipped with an automatic circumferential laser delivery modality, it aims at continuous circumferential PVI, improving both acute and clinical outcomes. We sought to evaluate the clinical efficacy of LB3 ablation using an anatomical-based approach without verifying electrical isolation. Methods Among 257 paroxysmal AF patients undergoing LB3 ablation across four Italian centres, 204 (72% male, mean age 60.4 ± and Results 11.1 years) were included. The primary endpoint was freedom from any atrial tachyarrhythmia (ATa) recurrence after the blanking period (BP), assessed with implantable cardiac monitors (ICMs). All pulmonary veins (PVs) were targeted using the LB3, with the RAPID mode used on an average of 96 ± 8, 86 ± 19, 98 ± 11, and 84 ± 15% for the left superior, left inferior, right superior, right inferior PV, and left common ostium, respectively. Freedom from arrhythmia recurrences was 84.8% at 1, 80.4% at 2, and 76.0% at 3 years. An ATa burden ≥ 5% was documented in 2.5, 4.4, and 5.4% at 1, 2, and 3 years, respectively. Relapses during the BP [hazard ratio (HR) = 2.182, P = 0.032] and left atrial dilation (HR = 1.964, P = 0.048) were independent predictors of recurrences. Conclusion Anatomical-guided LB3 ablation for paroxysmal AF is a safe and effective approach, providing excellent clinical outcomes as assessed by ICM over nearly 3 years of follow-up.

Anatomical-guided third-generation laser balloon ablation for the treatment of paroxysmal atrial fibrillation assessed by continuous rhythm monitoring: results from a multicentre prospective study / Ciconte, G.; Schiavone, M.; Rovaris, G.; Salerno, R.; Giaccardi, M.; Montemerlo, E.; Gasperetti, A.; Piazzi, E.; Negro, G.; Cartei, S.; Rondine, R.; Boccellino, A.; Mitacchione, G.; Pozzi, M.; Casiraghi, M.; De Ceglia, S.; Arosio, R.; Calovic, Z.; Vicedomini, G.; Forleo, G. B.; Pappone, C.. - In: EUROPACE. - ISSN 1099-5129. - 26:11(2024). [10.1093/europace/euae263]

Anatomical-guided third-generation laser balloon ablation for the treatment of paroxysmal atrial fibrillation assessed by continuous rhythm monitoring: results from a multicentre prospective study

Ciconte G.;Salerno R.;Boccellino A.;Pappone C.
2024-01-01

Abstract

Aims The third-generation laser balloon (LB3) is an established ablation device for pulmonary vein isolation (PVI) that allows direct visualization of the anatomical target. Equipped with an automatic circumferential laser delivery modality, it aims at continuous circumferential PVI, improving both acute and clinical outcomes. We sought to evaluate the clinical efficacy of LB3 ablation using an anatomical-based approach without verifying electrical isolation. Methods Among 257 paroxysmal AF patients undergoing LB3 ablation across four Italian centres, 204 (72% male, mean age 60.4 ± and Results 11.1 years) were included. The primary endpoint was freedom from any atrial tachyarrhythmia (ATa) recurrence after the blanking period (BP), assessed with implantable cardiac monitors (ICMs). All pulmonary veins (PVs) were targeted using the LB3, with the RAPID mode used on an average of 96 ± 8, 86 ± 19, 98 ± 11, and 84 ± 15% for the left superior, left inferior, right superior, right inferior PV, and left common ostium, respectively. Freedom from arrhythmia recurrences was 84.8% at 1, 80.4% at 2, and 76.0% at 3 years. An ATa burden ≥ 5% was documented in 2.5, 4.4, and 5.4% at 1, 2, and 3 years, respectively. Relapses during the BP [hazard ratio (HR) = 2.182, P = 0.032] and left atrial dilation (HR = 1.964, P = 0.048) were independent predictors of recurrences. Conclusion Anatomical-guided LB3 ablation for paroxysmal AF is a safe and effective approach, providing excellent clinical outcomes as assessed by ICM over nearly 3 years of follow-up.
2024
Atrial fibrillation
Continuous rhythm monitoring
Implantable cardiac monitors
Laser balloon ablation
Pulmonary vein isolation
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/198239
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 6
social impact