During the clinical examination of subjects with temporomandibular disorders (TMDs), the dentist sometimes must evaluate the cervical spine, due to the anatomical and functional connections between the cervical portion of the spine and the stomatognathic apparatus. The accelerometer is a device that evaluates the Range of Motion (ROM) of the main movements of the head on the neck. To date, only a few studies have investigated the repeatability of the use of the accelerometer in the assessment of cervical ROM. Therefore, the present longitudinal observational study analyzed the repeatability of acquired cervical movements on a sample of volunteer subjects who underwent accelerometer testing. A sample of 32 subjects was tested twice within 14 days to assess cervical ROM using a standardized protocol based on a review of existing literature. The results show that the examination is reliable for all the positions of the jaw, except for the parameters regarding the asymmetries of rotation and bending. In conclusion, the accelerometer can be considered a reliable tool for evaluating the active cervical ROM. However, further studies will be necessary to make better evaluations.

Cervical Range of Motion Analysis Performed with an Accelerometer: A Study of Intersession Reliability for Dental Practice / Nota, A.; Pittari, L.; Gamba, L.; Monticciolo, F. M.; Lannes, A.; Carta, C.; Beraldi, A.; Baldini, A.; Marzo, G.; Tecco, S.. - In: HEALTHCARE. - ISSN 2227-9032. - 11:10(2023). [10.3390/healthcare11101428]

Cervical Range of Motion Analysis Performed with an Accelerometer: A Study of Intersession Reliability for Dental Practice

Nota A.;Pittari L.;Monticciolo F. M.;Tecco S.
2023-01-01

Abstract

During the clinical examination of subjects with temporomandibular disorders (TMDs), the dentist sometimes must evaluate the cervical spine, due to the anatomical and functional connections between the cervical portion of the spine and the stomatognathic apparatus. The accelerometer is a device that evaluates the Range of Motion (ROM) of the main movements of the head on the neck. To date, only a few studies have investigated the repeatability of the use of the accelerometer in the assessment of cervical ROM. Therefore, the present longitudinal observational study analyzed the repeatability of acquired cervical movements on a sample of volunteer subjects who underwent accelerometer testing. A sample of 32 subjects was tested twice within 14 days to assess cervical ROM using a standardized protocol based on a review of existing literature. The results show that the examination is reliable for all the positions of the jaw, except for the parameters regarding the asymmetries of rotation and bending. In conclusion, the accelerometer can be considered a reliable tool for evaluating the active cervical ROM. However, further studies will be necessary to make better evaluations.
2023
accelerometer
cranio-cervical-mandibular disorders
digital dentistry
intersession reliability
range of motion
temporomandibular disorders
File in questo prodotto:
File Dimensione Formato  
healthcare-11-01428.pdf

accesso aperto

Tipologia: PDF editoriale (versione pubblicata dall'editore)
Licenza: Creative commons
Dimensione 1.25 MB
Formato Adobe PDF
1.25 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/198527
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact