Background: The outcomes of percutaneous coronary intervention (PCI) in diabetic patients are still suboptimal, and it is unclear if diabetic patients might derive a benefit from the use of drug-coated balloons. Aims: To evaluate the impact of diabetes mellitus on the outcomes of patients undergoing PCI with sirolimus-coated balloon (SCB) MagicTouch (Concept Medical, India). Methods: We conducted a subgroup analysis of the prospective, multicenter, investigator-initiated EASTBOURNE registry, evaluating the performance of MagicTouch SCB in patients with and without diabetes. The study primary endpoint was target lesion revascularization (TLR) at 12-month follow-up. Secondary clinical endpoints were major adverse clinical events (MACE), death, myocardial infarction (MI), and BARC 2–5 bleedings. Results: Among 2,083 enrolled patients, a total of 864 suffered from diabetes (41.5%). Patients with diabetes had a numerically higher occurrence of TLR (6.5% vs. 4.7% HR 1.38, 95%CI 0.91–2.08), all-cause death (3.8% vs. 2.6%, HR 1.81, 95%CI 0.95–3.46), and MACE (12.2% vs. 8.9%; HR 1.26 95%CI 0.92–1.74). The incidence of spontaneous MI was significantly higher among diabetic patients (3.4% vs. 1.5%, HR 2.15 95%CI 1.09–4.25); bleeding events did not significantly differ. The overall incidence of TLR was higher among in-stent restenosis (ISR) as compared to de-novo coronary lesions, irrespectively from diabetes status. Conclusions: In the EASTBOURNE DIABETES registry, diabetic patients treated with the MagicTouch SCB did not have a significant increase in TLR when compared to non-diabetic patients; moreover, diabetic status did not affect the study device performance in terms of TLR, in both de-novo lesions and ISR.

Sirolimus-coated balloon in all-comer population of coronary artery disease patients: the EASTBOURNE DIABETES prospective registry / Caiazzo, G.; Oliva, A.; Testa, L.; Heang, T. M.; Lee, C. Y.; Milazzo, D.; Stefanini, G.; Pesenti, N.; Mangieri, A.; Colombo, A.; Cortese, B.. - In: CARDIOVASCULAR DIABETOLOGY. - ISSN 1475-2840. - 23:1(2024). [10.1186/s12933-024-02139-9]

Sirolimus-coated balloon in all-comer population of coronary artery disease patients: the EASTBOURNE DIABETES prospective registry

Testa L.;Colombo A.;
2024-01-01

Abstract

Background: The outcomes of percutaneous coronary intervention (PCI) in diabetic patients are still suboptimal, and it is unclear if diabetic patients might derive a benefit from the use of drug-coated balloons. Aims: To evaluate the impact of diabetes mellitus on the outcomes of patients undergoing PCI with sirolimus-coated balloon (SCB) MagicTouch (Concept Medical, India). Methods: We conducted a subgroup analysis of the prospective, multicenter, investigator-initiated EASTBOURNE registry, evaluating the performance of MagicTouch SCB in patients with and without diabetes. The study primary endpoint was target lesion revascularization (TLR) at 12-month follow-up. Secondary clinical endpoints were major adverse clinical events (MACE), death, myocardial infarction (MI), and BARC 2–5 bleedings. Results: Among 2,083 enrolled patients, a total of 864 suffered from diabetes (41.5%). Patients with diabetes had a numerically higher occurrence of TLR (6.5% vs. 4.7% HR 1.38, 95%CI 0.91–2.08), all-cause death (3.8% vs. 2.6%, HR 1.81, 95%CI 0.95–3.46), and MACE (12.2% vs. 8.9%; HR 1.26 95%CI 0.92–1.74). The incidence of spontaneous MI was significantly higher among diabetic patients (3.4% vs. 1.5%, HR 2.15 95%CI 1.09–4.25); bleeding events did not significantly differ. The overall incidence of TLR was higher among in-stent restenosis (ISR) as compared to de-novo coronary lesions, irrespectively from diabetes status. Conclusions: In the EASTBOURNE DIABETES registry, diabetic patients treated with the MagicTouch SCB did not have a significant increase in TLR when compared to non-diabetic patients; moreover, diabetic status did not affect the study device performance in terms of TLR, in both de-novo lesions and ISR.
2024
Inglese
BioMed Central Ltd
23
1
Pubblicato
Esperti anonimi
Internazionale
Goal 3: Good health and well-being
Coronary artery disease
Diabetes mellitus
Drug-coated balloon
Sirolimus-coated balloon in all-comer population of coronary artery disease patients: the EASTBOURNE DIABETES prospective registry / Caiazzo, G.; Oliva, A.; Testa, L.; Heang, T. M.; Lee, C. Y.; Milazzo, D.; Stefanini, G.; Pesenti, N.; Mangieri, A.; Colombo, A.; Cortese, B.. - In: CARDIOVASCULAR DIABETOLOGY. - ISSN 1475-2840. - 23:1(2024). [10.1186/s12933-024-02139-9]
none
11
info:eu-repo/semantics/article
262
Caiazzo, G.; Oliva, A.; Testa, L.; Heang, T. M.; Lee, C. Y.; Milazzo, D.; Stefanini, G.; Pesenti, N.; Mangieri, A.; Colombo, A.; Cortese, B.
1 Contributo su Rivista::1.1 Articolo in rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/198543
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 11
social impact