Radioguided surgery (RGS) using prostate-specific membrane antigen (PSMA)-targeted tracers is frequently hampered by relatively low intraoperative signal intensities. This limits intraoperative target discrimination when feedback relies solely on probe counts per second. We evaluated whether real-time signal-to-background ratio (SBR) feedback, integrated into the robotic console via a graphical user interface (GUI), improves surgical perception, decisiveness, and scanning efficiency during drop-in PSMA-radioguided procedures. Methods: We retrospectively analyzed 10 patients from the TRACE-II trial undergoing salvage RGS with 99mTc-PSMA imaging and surgery. Five procedures were performed with standard counts per second feedback (control group), and 5 were performed with additional live SBR feedback (experiment group). The GUI enabled intraoperative background sampling and displayed real-time SBRs via a traffic light-style color-coded gauge. Probe trajectories were reconstructed using video-based tracking with green polyetheretherketone marker rings, and scanning performance was quantified by total scan duration and target scan duration. Statistical comparisons were made using Mann-Whitney U and Spearman correlation analyses. Results: Fourteen PSMA-avid lesions were resected, all of which were confirmed by pathology as cancerous. Cases with real-time SBR feedback showed more focused probe trajectories and reduced procedure times. The median total scan duration decreased from 455 to 237 s (P = 0.11), and the median target scan duration decreased from 299 to 212 s (P = 0.15). Although not statistically significant in this pilot study, scan durations strongly correlated with in vivo counts (Spearman ρ = -0.74, P = 0.01). After normalization for maximum in vivo counts, median target scan duration decreased from 21.1 to 5.3 seconds per counts per second (s/cps) (P = 0.08). Conclusion: Streaming real-time SBR feedback into the robotic console improved surgical decisiveness and perception of PSMA-avid lesions and facilitated more efficient probe handling. By digitizing intraoperative contrast information, the drop-in γ-probe provided actionable feedback that reduced cognitive load and enhanced target discrimination. These findings support future multicenter studies to establish standardized SBR-based performance metrics in RGS.

Actionable Feedback on Signal-to-Background Ratios During Drop-in Radioguided Surgery / Cakal, B.A., Pirkovets, K., Ottens, V.A., Zuur, L., Sinaasappel, M., Gandaglia, G., Briganti, A., Van Der Poel, H.G., Van Leeuwen, P.J., Van Leeuwen, F.W.B.. - In: THE JOURNAL OF NUCLEAR MEDICINE. - ISSN 1535-5667. - 67:6(2026), pp. 864-870. [10.2967/jnumed.125.271693]

Actionable Feedback on Signal-to-Background Ratios During Drop-in Radioguided Surgery

Gandaglia G.;Briganti A.;
2026-01-01

Abstract

Radioguided surgery (RGS) using prostate-specific membrane antigen (PSMA)-targeted tracers is frequently hampered by relatively low intraoperative signal intensities. This limits intraoperative target discrimination when feedback relies solely on probe counts per second. We evaluated whether real-time signal-to-background ratio (SBR) feedback, integrated into the robotic console via a graphical user interface (GUI), improves surgical perception, decisiveness, and scanning efficiency during drop-in PSMA-radioguided procedures. Methods: We retrospectively analyzed 10 patients from the TRACE-II trial undergoing salvage RGS with 99mTc-PSMA imaging and surgery. Five procedures were performed with standard counts per second feedback (control group), and 5 were performed with additional live SBR feedback (experiment group). The GUI enabled intraoperative background sampling and displayed real-time SBRs via a traffic light-style color-coded gauge. Probe trajectories were reconstructed using video-based tracking with green polyetheretherketone marker rings, and scanning performance was quantified by total scan duration and target scan duration. Statistical comparisons were made using Mann-Whitney U and Spearman correlation analyses. Results: Fourteen PSMA-avid lesions were resected, all of which were confirmed by pathology as cancerous. Cases with real-time SBR feedback showed more focused probe trajectories and reduced procedure times. The median total scan duration decreased from 455 to 237 s (P = 0.11), and the median target scan duration decreased from 299 to 212 s (P = 0.15). Although not statistically significant in this pilot study, scan durations strongly correlated with in vivo counts (Spearman ρ = -0.74, P = 0.01). After normalization for maximum in vivo counts, median target scan duration decreased from 21.1 to 5.3 seconds per counts per second (s/cps) (P = 0.08). Conclusion: Streaming real-time SBR feedback into the robotic console improved surgical decisiveness and perception of PSMA-avid lesions and facilitated more efficient probe handling. By digitizing intraoperative contrast information, the drop-in γ-probe provided actionable feedback that reduced cognitive load and enhanced target discrimination. These findings support future multicenter studies to establish standardized SBR-based performance metrics in RGS.
2026
Inglese
67
6
864
870
7
Pubblicato
Esperti anonimi
Internazionale
Not applicable
drop-in γ-probe
prostate cancer
PSMA
radioguided surgery
robotic surgery
Actionable Feedback on Signal-to-Background Ratios During Drop-in Radioguided Surgery / Cakal, B.A., Pirkovets, K., Ottens, V.A., Zuur, L., Sinaasappel, M., Gandaglia, G., Briganti, A., Van Der Poel, H.G., Van Leeuwen, P.J., Van Leeuwen, F.W.B.. - In: THE JOURNAL OF NUCLEAR MEDICINE. - ISSN 1535-5667. - 67:6(2026), pp. 864-870. [10.2967/jnumed.125.271693]
none
10
info:eu-repo/semantics/article
262
Cakal, B. A.; Pirkovets, K.; Ottens, V. A.; Zuur, L.; Sinaasappel, M.; Gandaglia, G.; Briganti, A.; Van Der Poel, H. G.; Van Leeuwen, P. J.; Van Leeuw...espandi
1 Contributo su Rivista::1.1 Articolo in rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/206985
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact