Introduction and aims: This multicenter randomized controlled trial compared the clinical effectiveness of 7.0-mm wide-diameter implants with 5.0-mm conventional-diameter implants placed immediately after molar extraction. Methods: Thirty-nine patients needing a single immediate post-extraction implant in a molar site were recruited at five centers. Patients were randomly assigned to receive either a 7.0-mm implant (n = 19) or a 5.0-mm implant (n = 20). Any gaps between bone and implant were grafted with a bone substitute. Definitive zirconia crowns were delivered 4 months after implant placement. Outcomes were assessed 1 year after loading and included implant failures, complications, patient satisfaction, changes in peri-implant marginal bone level (MBL), and pink esthetic score (PES). Results: No patient dropped out. No implant failed in the 7-mm group, whereas one implant failed in the 5-mm group (difference = 5.0%; 95% CI: -4.6% to 14.6%; P = 1.000). Four complications occurred in four patients in the 7-mm group versus zero in the 5-mm group, with the difference being statistically significant (difference = 21.1%; 95% CI: 2.7% to 39.4%; P = 0.047). At loading, mean PES was 5.84 ± 2.34 in the 7-mm group and 6.06 ± 4.04 in the 5-mm group, with no significant difference between groups (mean difference = 0.21; 95% CI: -2.03 to 2.45; P = 0.847). At 1 year, the mean PES score was 9.16 ± 2.22 in the 7-mm group and 9.21 ± 2.88 in the 5-mm group (mean difference = 0.05; 95% CI: -1.64 to 1.75; P = 0.950). Mean peri-implant marginal bone loss was 0.83 ± 1.56 mm and 0.45 ± 1.19 mm, respectively (mean difference = 0.39 mm; 95% CI: -0.53 to 1.30; P = 0.396). Conclusion: Preliminary 1-year data showed similar implant survival, esthetic outcomes, and marginal bone loss between 7-mm and 5-mm diameter implants. However, a higher number of minor complications was observed in the 7-mm group. Given the small sample size, larger randomized clinical trials are needed to confirm these findings.

7-mm-Diamater Versus 5-mm-Diameter Immediate Post-Extraction Implants in the Molar Region: 1-Year Results from a Multicenter Randomized Controlled Trial / Esposito, M., Bocari, A., Cho, Y., Park, B., Kim, J., Greco, K., Visconti, R.F., Chang, D.. - In: THE INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS. - ISSN 0882-2786. - 0:0(2026), pp. 1-32. [Epub ahead of print] [10.11607/jomi.11536]

7-mm-Diamater Versus 5-mm-Diameter Immediate Post-Extraction Implants in the Molar Region: 1-Year Results from a Multicenter Randomized Controlled Trial

Esposito, Marco
;
Visconti, Riccardo Federico;
2026-01-01

Abstract

Introduction and aims: This multicenter randomized controlled trial compared the clinical effectiveness of 7.0-mm wide-diameter implants with 5.0-mm conventional-diameter implants placed immediately after molar extraction. Methods: Thirty-nine patients needing a single immediate post-extraction implant in a molar site were recruited at five centers. Patients were randomly assigned to receive either a 7.0-mm implant (n = 19) or a 5.0-mm implant (n = 20). Any gaps between bone and implant were grafted with a bone substitute. Definitive zirconia crowns were delivered 4 months after implant placement. Outcomes were assessed 1 year after loading and included implant failures, complications, patient satisfaction, changes in peri-implant marginal bone level (MBL), and pink esthetic score (PES). Results: No patient dropped out. No implant failed in the 7-mm group, whereas one implant failed in the 5-mm group (difference = 5.0%; 95% CI: -4.6% to 14.6%; P = 1.000). Four complications occurred in four patients in the 7-mm group versus zero in the 5-mm group, with the difference being statistically significant (difference = 21.1%; 95% CI: 2.7% to 39.4%; P = 0.047). At loading, mean PES was 5.84 ± 2.34 in the 7-mm group and 6.06 ± 4.04 in the 5-mm group, with no significant difference between groups (mean difference = 0.21; 95% CI: -2.03 to 2.45; P = 0.847). At 1 year, the mean PES score was 9.16 ± 2.22 in the 7-mm group and 9.21 ± 2.88 in the 5-mm group (mean difference = 0.05; 95% CI: -1.64 to 1.75; P = 0.950). Mean peri-implant marginal bone loss was 0.83 ± 1.56 mm and 0.45 ± 1.19 mm, respectively (mean difference = 0.39 mm; 95% CI: -0.53 to 1.30; P = 0.396). Conclusion: Preliminary 1-year data showed similar implant survival, esthetic outcomes, and marginal bone loss between 7-mm and 5-mm diameter implants. However, a higher number of minor complications was observed in the 7-mm group. Given the small sample size, larger randomized clinical trials are needed to confirm these findings.
2026
Aesthetics
Immediate placement
Randomised controlled clinical trial
Single implant
Wide diameter implant
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/208636
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact