"Objective: The authors measured cardiac index in unstable patients after cardiac surgery with the Pressure Recording Analytic Method (PRAM) and compared it with the reference method of thermodilution (ThD) with the pulmonary artery catheter; using the hypothesis that there were no significant differences between the 2 methods. Design: A prospective study. Setting: Cardiac surgery intensive care unit in a teaching hospital. Participants: Ninety-four measurements from 59 patients with ongoing high doses of inotropic drugs and\/or an intra-aortic balloon pump for low-cardiac-output syndrome after cardiac surgery were studied. Interventions: The pulmonary artery catheter and the radial or femoral arterial catheter for measuring blood pressure were already in place for standard hemodynamic monitoring. Measurements and Main Results: The mean of the total Cl measurements was 2.94 +\/- 0.67 L\/min\/m(2) with PRAM and 2.95 +\/- 0.63 L\/min\/m(2) with ThD, with no significant difference according to the linear mixed models analysis. The PRAM and ThD techniques were similar in unstable patients without atrial fibrillation (mean bias 0.047 +\/- 0.395 L\/min\/m(2) and a percentage error of 29%), while no agreement between PRAM and ThD was found in unstable patients with atrial fibrillation (mean bias 0.195 +\/- 0.885 L\/min\/m(2) and a percentage error of 69%). Conclusion: Cardiac index measurements after cardiac surgery performed with PRAM and with ThD showed a good agreement in hemodynamically unstable patients given high doses of inotropes and\/or an IABP in patients in sinus rhythm, but not in those with atrial fibrillation. (C) 2013 Elsevier Inc. All rights reserved."

Cardiac Index Assessment by the Pressure Recording Analytic Method in Critically Ill Unstable Patients After Cardiac Surgery

LANDONI, GIOVANNI;Pieri M;ZANGRILLO, ALBERTO
2013-01-01

Abstract

"Objective: The authors measured cardiac index in unstable patients after cardiac surgery with the Pressure Recording Analytic Method (PRAM) and compared it with the reference method of thermodilution (ThD) with the pulmonary artery catheter; using the hypothesis that there were no significant differences between the 2 methods. Design: A prospective study. Setting: Cardiac surgery intensive care unit in a teaching hospital. Participants: Ninety-four measurements from 59 patients with ongoing high doses of inotropic drugs and\/or an intra-aortic balloon pump for low-cardiac-output syndrome after cardiac surgery were studied. Interventions: The pulmonary artery catheter and the radial or femoral arterial catheter for measuring blood pressure were already in place for standard hemodynamic monitoring. Measurements and Main Results: The mean of the total Cl measurements was 2.94 +\/- 0.67 L\/min\/m(2) with PRAM and 2.95 +\/- 0.63 L\/min\/m(2) with ThD, with no significant difference according to the linear mixed models analysis. The PRAM and ThD techniques were similar in unstable patients without atrial fibrillation (mean bias 0.047 +\/- 0.395 L\/min\/m(2) and a percentage error of 29%), while no agreement between PRAM and ThD was found in unstable patients with atrial fibrillation (mean bias 0.195 +\/- 0.885 L\/min\/m(2) and a percentage error of 69%). Conclusion: Cardiac index measurements after cardiac surgery performed with PRAM and with ThD showed a good agreement in hemodynamically unstable patients given high doses of inotropes and\/or an IABP in patients in sinus rhythm, but not in those with atrial fibrillation. (C) 2013 Elsevier Inc. All rights reserved."
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/47405
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 18
social impact