Ligand gated ion channels are involved in many pathophysiological processes and represent a relevant, although challenging, target for drug discovery. We propose an innovative electro-optical approach to their analysis able to derive membrane conductance values from the local membrane potential changes imposed by test current pulses and measured by fast voltage-sensitive fluorescent dyes. We exploited the potential of this proprietary method by developing a drug testing system called "ionChannel Optical High-content Microscope" (ionChannelω). This automated platform was validated by testing the responses of reference drugs on cells expressing different ligand-gated ion channels. Furthermore, a double-blind comparison with FLIPR and automated patch-clamp was performed on molecules designed to act as antagonists of the P2RX7 receptor. ionChannelω proved highly reliable in all tests, resulting faster and more cost-effective than electrophysiological techniques. Overall, ionChannelω is amenable to the study of ligand gated ion channels that are receiving less attention due to limitations in current assays.

A new electro-optical approach for conductance measurement: An assay for the study of drugs acting on ligand-gated ion channels

GROHOVAZ, FABIO
2017-01-01

Abstract

Ligand gated ion channels are involved in many pathophysiological processes and represent a relevant, although challenging, target for drug discovery. We propose an innovative electro-optical approach to their analysis able to derive membrane conductance values from the local membrane potential changes imposed by test current pulses and measured by fast voltage-sensitive fluorescent dyes. We exploited the potential of this proprietary method by developing a drug testing system called "ionChannel Optical High-content Microscope" (ionChannelω). This automated platform was validated by testing the responses of reference drugs on cells expressing different ligand-gated ion channels. Furthermore, a double-blind comparison with FLIPR and automated patch-clamp was performed on molecules designed to act as antagonists of the P2RX7 receptor. ionChannelω proved highly reliable in all tests, resulting faster and more cost-effective than electrophysiological techniques. Overall, ionChannelω is amenable to the study of ligand gated ion channels that are receiving less attention due to limitations in current assays.
2017
Inglese
7
44843
www.nature.com/srep/index.html
Esperti anonimi
Internazionale
Multidisciplinary
No
none
10
info:eu-repo/semantics/article
262
Menegon, A.; Pitassi, S.; Mazzocchi, N.; Redaelli, L.; Rizzetto, R.; Rolland, J. F.; Poli, C.; Imberti, M.; Lanati, A.; Grohovaz, Fabio
1 Contributo su Rivista::1.1 Articolo in rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/58820
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact