Background. Non-invasive ventilation (NIV) can prevent or treat postoperative acute respiratory failure. NIV after discharge from the Intensive Care Unit (ICU) has never been described in the setting of cardiac surgery. Methods. This study enrolled 85 patients who received NIV in the main ward as treatment for respiratory failure. The patients had the following conditions: atelectasis (45 patients), pleural effusion (20 patients), pulmonary congestion (13 patients), diaphragm hemiparesis (6 patients), pneumonia (4 patients) or a combination of these conditions. Results. Eighty-three patients were discharged from the hospital in good condition and without need for further NIV treatment, while two died in-hospital. Four of the 85 patients had an immediate NIV failure, while eight patients had delayed NIV failure. Only one patient had a NIV-related complication represented by hypotension after NIV institution. In this patient, NIV was interrupted with no consequences. Major mistakes were mask mal-positioning with excessive air leaks (7 patients), incorrect preparation of the circuit (one patient), and oxygen tube disconnection (one patient). Minor mistakes (sub-optimal positioning of the face mask without excessive air leaks) were noted by the respiratory therapists for all patients and were managed by slightly modifying the mask position. Conclusion. In our experience, postoperative NIV is feasible, safe and effective in treating postoperative acute respiratory failure when applied in the cardiac surgical ward, preserving intensive care unit beds for surgical activity. A respiratory therapy service managed the treatment in conjunction with ward nurses, while an anesthesiologist and a cardiologist served as consultants. (Minerva Anestesiol 2011;77:40-5)

Non-invasive ventilation after cardiac surgery outside the Intensive Care Unit

LANDONI, GIOVANNI;Monti G;ALFIERI, OTTAVIO;ZANGRILLO, ALBERTO
2011-01-01

Abstract

Background. Non-invasive ventilation (NIV) can prevent or treat postoperative acute respiratory failure. NIV after discharge from the Intensive Care Unit (ICU) has never been described in the setting of cardiac surgery. Methods. This study enrolled 85 patients who received NIV in the main ward as treatment for respiratory failure. The patients had the following conditions: atelectasis (45 patients), pleural effusion (20 patients), pulmonary congestion (13 patients), diaphragm hemiparesis (6 patients), pneumonia (4 patients) or a combination of these conditions. Results. Eighty-three patients were discharged from the hospital in good condition and without need for further NIV treatment, while two died in-hospital. Four of the 85 patients had an immediate NIV failure, while eight patients had delayed NIV failure. Only one patient had a NIV-related complication represented by hypotension after NIV institution. In this patient, NIV was interrupted with no consequences. Major mistakes were mask mal-positioning with excessive air leaks (7 patients), incorrect preparation of the circuit (one patient), and oxygen tube disconnection (one patient). Minor mistakes (sub-optimal positioning of the face mask without excessive air leaks) were noted by the respiratory therapists for all patients and were managed by slightly modifying the mask position. Conclusion. In our experience, postoperative NIV is feasible, safe and effective in treating postoperative acute respiratory failure when applied in the cardiac surgical ward, preserving intensive care unit beds for surgical activity. A respiratory therapy service managed the treatment in conjunction with ward nurses, while an anesthesiologist and a cardiologist served as consultants. (Minerva Anestesiol 2011;77:40-5)
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/6129
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 27
  • ???jsp.display-item.citation.isi??? 21
social impact