Objectives The aim of this study was to explore the incidence, causes, and outcomes of cardiac tamponade in patients undergoing transcatheter aortic valve implantation (TAVI). Background Use of TAVI is increasing, but the procedure is vulnerable to complications, given the cohort of patients. Cardiac tamponade is a possible complication, and there is a scarcity of data on the incidence and outcomes of cardiac tamponade during TAVI. Methods All patients who sustained cardiac tamponade during or post-TAVI between 2007 and 2012 were included in the study. Results Of 389 patients who underwent TAVI, 17 (4.3%) had cardiac tamponade. The mean age was 82.3 +/- 3.7 years, and most were women (n = 12, 70.6%). Causes of cardiac tamponade were right ventricular perforation by temporary pacemaker (9 patients, 52.9%), annular rupture or aortic dissection (4 patients, 23.5%), and tear in the left ventricular free wall caused by Amplatz stiff wire or catheters (4 patients, 23.5%). Mortality occurred in 4 patients (23.5%), and all had tamponade caused by injury to the high-pressured left-sided circulation (left ventricle and aorta). Most patients (n = 14, 82.4%) sustained cardiac tamponade during the procedure-2 patients (11.7%) within 24 h, and 1 patient after 24 h. Conclusions Cardiac tamponade during TAVI is not frequent but is associated with high mortality rates especially when left-sided structures are involved. Meticulous handling of the equipment and improvements in the safety of currently used devices could further reduce the occurrence of this complication. (J Am Coll Cardiol Intv 2012;5:1264-72) (C) 2012 by the American College of Cardiology Foundation

Incidence, Management, and Outcomes of Cardiac Tamponade During Transcatheter Aortic Valve Implantation A Single-Center Study

Montorfano M;Chieffo A;Maisano F;ALFIERI , OTTAVIO;
2012-01-01

Abstract

Objectives The aim of this study was to explore the incidence, causes, and outcomes of cardiac tamponade in patients undergoing transcatheter aortic valve implantation (TAVI). Background Use of TAVI is increasing, but the procedure is vulnerable to complications, given the cohort of patients. Cardiac tamponade is a possible complication, and there is a scarcity of data on the incidence and outcomes of cardiac tamponade during TAVI. Methods All patients who sustained cardiac tamponade during or post-TAVI between 2007 and 2012 were included in the study. Results Of 389 patients who underwent TAVI, 17 (4.3%) had cardiac tamponade. The mean age was 82.3 +/- 3.7 years, and most were women (n = 12, 70.6%). Causes of cardiac tamponade were right ventricular perforation by temporary pacemaker (9 patients, 52.9%), annular rupture or aortic dissection (4 patients, 23.5%), and tear in the left ventricular free wall caused by Amplatz stiff wire or catheters (4 patients, 23.5%). Mortality occurred in 4 patients (23.5%), and all had tamponade caused by injury to the high-pressured left-sided circulation (left ventricle and aorta). Most patients (n = 14, 82.4%) sustained cardiac tamponade during the procedure-2 patients (11.7%) within 24 h, and 1 patient after 24 h. Conclusions Cardiac tamponade during TAVI is not frequent but is associated with high mortality rates especially when left-sided structures are involved. Meticulous handling of the equipment and improvements in the safety of currently used devices could further reduce the occurrence of this complication. (J Am Coll Cardiol Intv 2012;5:1264-72) (C) 2012 by the American College of Cardiology Foundation
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/6187
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 88
  • ???jsp.display-item.citation.isi??? 75
social impact