This paper focuses on acquisition and processing methods in positron emission tomography/computed tomography (PET/CT) for radiotherapy (RT) applications. The recent technological evolutions of PET/CT systems are described. Particular emphasis is dedicated to the tools needed for the patient positioning and immobilization, to be used in PET/CT studies as well as during RT treatment sessions. The effect of organ and lesion motion due to patient's respiration on PET/CT imaging is discussed. Breathing protocols proposed to minimize PET/CT spatial mismatches in relation to respiratory movements are illustrated. The respiratory gated (RG) 4D-PET/CT techniques, developed to measure and compensate for organ and lesion motion, are then introduced. Finally a description is provided of different acquisition and data processing techniques, implemented with the aim at improving: i) image quality and quantitative accuracy of PET images, and ii) target volume definition and treatment planning in RT, by using specific and personalised motion information.

PET/CT for radiotherapy: image acquisition and data processing / Bettinardi, V; Picchio, M; Di Muzio, N; Gianolli, L; Messa, C; Gilardi, Mc. - In: THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING. - ISSN 1824-4785. - 54:5(2010), pp. 455-475.

PET/CT for radiotherapy: image acquisition and data processing

Picchio M;Di Muzio N;
2010-01-01

Abstract

This paper focuses on acquisition and processing methods in positron emission tomography/computed tomography (PET/CT) for radiotherapy (RT) applications. The recent technological evolutions of PET/CT systems are described. Particular emphasis is dedicated to the tools needed for the patient positioning and immobilization, to be used in PET/CT studies as well as during RT treatment sessions. The effect of organ and lesion motion due to patient's respiration on PET/CT imaging is discussed. Breathing protocols proposed to minimize PET/CT spatial mismatches in relation to respiratory movements are illustrated. The respiratory gated (RG) 4D-PET/CT techniques, developed to measure and compensate for organ and lesion motion, are then introduced. Finally a description is provided of different acquisition and data processing techniques, implemented with the aim at improving: i) image quality and quantitative accuracy of PET images, and ii) target volume definition and treatment planning in RT, by using specific and personalised motion information.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/63381
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 12
social impact