Background Transfemoral transcatheter aortic valve replacement (TF-TAVR) has enjoyed a rapid diffusion in the US and Europe, but the procedure is resource intensive. Objectives We sought to identify differences in resource utilization between a US and European center to ascertain opportunities for improvement in the performance of TF-TAVR. Methods All patients undergoing TF-TAVR using the Edwards SAPIEN valve series at the San Raffaele Hospital (Milan, Italy) and the Cleveland Clinic Foundation (Cleveland, OH) between January 2011 and December 2012 were included. Resource utilization was defined as preprocedural imaging, intraprocedural imaging, and personnel present during the procedure. Results A total of 158 patients from Cleveland and 113 from Milan were analyzed. Median logistic EuroScore (22.1 vs. 15.5, P = 0.013) and STS-PROM (8.9 vs. 5.0%, P < 0.001) were higher in Cleveland. Thirty-day outcomes were similar. Majority of procedures in Milan were conducted without a cardiac surgeon (79%) or an imaging specialist (99%) present during the case. There was greater reliance on endotracheal intubation (94.3 vs. 3.5%), general anesthesia (GA: 94.3 vs. 4.4%), and intraprocedural TEE (93 vs. 12.4%) in Cleveland, but shorter length of stay (mean: 6.42 vs. 11.16 days). Conclusions We characterized resources used for patients undergoing TF-TAVR in Cleveland and Milan. Important differences included less reliance on GA and TEE and streamlining of procedural personnel in Milan, and reduced length-of-stay in Cleveland. Evolution of TF-TAVR to involve fewer operators must be balanced with the need for ready access to a comprehensive group of specialists in case of emergencies.

Resource utilization for transfemoral transcatheter aortic valve replacement: An international comparison / Krishnaswamy, Amar; Latib, Azeem; Malik, Ali; Bertoldi, Letizia; Poddar, Kanhaiya L.; Chieffo, Alaide; Montorfano, Matteo; Svensson, Lars G.; Alfieri, Ottavio; Colombo, Antonio; Tuzcu, E. Murat; Kapadia, Samir R.. - In: CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS. - ISSN 1522-1946. - 87:1(2016), pp. 145-151. [10.1002/ccd.26056]

Resource utilization for transfemoral transcatheter aortic valve replacement: An international comparison

Chieffo, Alaide;Montorfano, Matteo;ALFIERI, OTTAVIO;COLOMBO, ANTONIO;
2016-01-01

Abstract

Background Transfemoral transcatheter aortic valve replacement (TF-TAVR) has enjoyed a rapid diffusion in the US and Europe, but the procedure is resource intensive. Objectives We sought to identify differences in resource utilization between a US and European center to ascertain opportunities for improvement in the performance of TF-TAVR. Methods All patients undergoing TF-TAVR using the Edwards SAPIEN valve series at the San Raffaele Hospital (Milan, Italy) and the Cleveland Clinic Foundation (Cleveland, OH) between January 2011 and December 2012 were included. Resource utilization was defined as preprocedural imaging, intraprocedural imaging, and personnel present during the procedure. Results A total of 158 patients from Cleveland and 113 from Milan were analyzed. Median logistic EuroScore (22.1 vs. 15.5, P = 0.013) and STS-PROM (8.9 vs. 5.0%, P < 0.001) were higher in Cleveland. Thirty-day outcomes were similar. Majority of procedures in Milan were conducted without a cardiac surgeon (79%) or an imaging specialist (99%) present during the case. There was greater reliance on endotracheal intubation (94.3 vs. 3.5%), general anesthesia (GA: 94.3 vs. 4.4%), and intraprocedural TEE (93 vs. 12.4%) in Cleveland, but shorter length of stay (mean: 6.42 vs. 11.16 days). Conclusions We characterized resources used for patients undergoing TF-TAVR in Cleveland and Milan. Important differences included less reliance on GA and TEE and streamlining of procedural personnel in Milan, and reduced length-of-stay in Cleveland. Evolution of TF-TAVR to involve fewer operators must be balanced with the need for ready access to a comprehensive group of specialists in case of emergencies.
2016
AVD aortic valve disease; AVDP aortic valve disease percutaneous intervention; electron beam CT/multidetector CT; ICT imaging; Aged, 80 and over; Aortic Valve Stenosis; Female; Femoral Artery; Follow-Up Studies; Health Resources; Humans; Italy; Kaplan-Meier Estimate; Male; Retrospective Studies; Risk Factors; Survival Rate; Transcatheter Aortic Valve Replacement; Heart Valve Prosthesis; Radiology, Nuclear Medicine and Imaging; Cardiology and Cardiovascular Medicine
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/64161
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact