Bioresorbable vascular scaffolds (BVS) have become an attractive option in the percutaneous coronary intervention field due to the potential advantages associated with the complete resorption process that occurs within a few years. However, current-generation BVS have several limitations including thicker struts, reduced radial strength, and limited expansion capability when compared with drug-eluting stents (DES). As a result, complex coronary disease often contains BVS-inappropriate/unfavorable segments. This does not necessarily mean that BVS use must be completely avoided, and minimizing the length of permanent metallic caging may still be advantageous. Operators should fully understand the limitations of current BVS, and when to consider a hybrid strategy of BVS in combination with DES or drug-coated balloons.

Hybrid Percutaneous Coronary Intervention With Bioresorbable Vascular Scaffolds in Combination With Drug-Eluting Stents or Drug-Coated Balloons for Complex Coronary Lesions

COLOMBO, ANTONIO
Ultimo
2017-01-01

Abstract

Bioresorbable vascular scaffolds (BVS) have become an attractive option in the percutaneous coronary intervention field due to the potential advantages associated with the complete resorption process that occurs within a few years. However, current-generation BVS have several limitations including thicker struts, reduced radial strength, and limited expansion capability when compared with drug-eluting stents (DES). As a result, complex coronary disease often contains BVS-inappropriate/unfavorable segments. This does not necessarily mean that BVS use must be completely avoided, and minimizing the length of permanent metallic caging may still be advantageous. Operators should fully understand the limitations of current BVS, and when to consider a hybrid strategy of BVS in combination with DES or drug-coated balloons.
2017
bioresorbable scaffold; drug-coated balloon; drug-eluting stent(s); Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Humans; Patient Selection; Prosthesis Design; Risk Assessment; Risk Factors; Tomography, Optical Coherence; Treatment Outcome; Ultrasonography, Interventional; Absorbable Implants; Cardiac Catheters; Coated Materials, Biocompatible; Drug-Eluting Stents; Cardiology and Cardiovascular Medicine
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/65452
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 9
social impact