PURPOSE:We compared [11C]choline-positron emission tomography (PET) with [18F]fluorodeoxyglucose-PET for re-staging prostate cancer in a group of 100 patients.MATERIALS AND METHODS:A total of 100 consecutive patients referred for whole body [18F]fluorodeoxyglucose-PET for clinical prostate re-staging after radical treatment for prostate cancer were retrospectively included in the study. Mean prostate specific antigen (PSA) was 6.57 ng./ml. In all cases [11C]choline-PET was also performed. PET studies were done with a multiring device 5 minutes after intravenous injection of approximately 370 MBq. [11C]choline and 60 minutes after injection of approximately 370 MBq. [18F]fluorodeoxyglucose. PET findings were compared with those obtained with different conventional imaging and with PSA assessed at the time of PET and 1 year later.RESULTS:Areas of abnormal focal increases were noted in 47% of patients on [11C]choline-PET and in 27% on [18F]fluorodeoxyglucose-PET. Of the 100 patients 49 had positive conventional imaging findings. All except 14 [11C]choline-PET findings were concordant with conventional imaging, including 6 negative and 8 positive conventional imaging results. All except 1 [11C]choline-PET negative cases also had negative conventional imaging after 1 year. PSA at 1 year remained stable or decreased in 80% and 62% of [11C]choline-PET negative and positive cases, respectively.CONCLUSIONS:[11C]choline-PET seems to be useful for re-staging prostatectomy cases with increasing serum PSA levels. It is superior to [18F]fluorodeoxyglucose-PET and complementary to conventional imaging but with the advantage of staging disease at a single step

Value of [C-11]choline-positron emission tomography for re-staging prostate cancer: A comparison with [F-18]fluorodeoxyglucose-positron emission tomography

Picchio, M;DE COBELLI, FRANCESCO;DEL MASCHIO, ALESSANDRO;RIGATTI, PATRIZIO;
2003-01-01

Abstract

PURPOSE:We compared [11C]choline-positron emission tomography (PET) with [18F]fluorodeoxyglucose-PET for re-staging prostate cancer in a group of 100 patients.MATERIALS AND METHODS:A total of 100 consecutive patients referred for whole body [18F]fluorodeoxyglucose-PET for clinical prostate re-staging after radical treatment for prostate cancer were retrospectively included in the study. Mean prostate specific antigen (PSA) was 6.57 ng./ml. In all cases [11C]choline-PET was also performed. PET studies were done with a multiring device 5 minutes after intravenous injection of approximately 370 MBq. [11C]choline and 60 minutes after injection of approximately 370 MBq. [18F]fluorodeoxyglucose. PET findings were compared with those obtained with different conventional imaging and with PSA assessed at the time of PET and 1 year later.RESULTS:Areas of abnormal focal increases were noted in 47% of patients on [11C]choline-PET and in 27% on [18F]fluorodeoxyglucose-PET. Of the 100 patients 49 had positive conventional imaging findings. All except 14 [11C]choline-PET findings were concordant with conventional imaging, including 6 negative and 8 positive conventional imaging results. All except 1 [11C]choline-PET negative cases also had negative conventional imaging after 1 year. PSA at 1 year remained stable or decreased in 80% and 62% of [11C]choline-PET negative and positive cases, respectively.CONCLUSIONS:[11C]choline-PET seems to be useful for re-staging prostatectomy cases with increasing serum PSA levels. It is superior to [18F]fluorodeoxyglucose-PET and complementary to conventional imaging but with the advantage of staging disease at a single step
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/6594
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 293
  • ???jsp.display-item.citation.isi??? 252
social impact