BACKGROUND AND OBJECTIVE: To evaluate the effects of DualTrack Motion Correction Technology on the performance of AngioVue optical coherence tomography angiography (Optovue, Freemont, CA). PATIENTS AND METHODS: Fifty subjects underwent two consecutive examinations with AngioVue. The operator inactivated the eye-tracking (ET) technology before the second examination. Two operators measured execution time, excluded low-quality images, and counted the number of motion artifacts per image. RESULTS: The mean execution time was lower without ET in all the groups (P < .05), regardless of retinal diseases. Percentages of available images and low-quality images were 75.0% and 25.0%, respectively, with ET and 63.0% and 37.0%, respectively, without ET. Mean number of motion artifacts was significantly lower in images obtained using ET compared to images obtained without ET in all the groups (P < .0001), regardless of retinal diseases. CONCLUSION: Although ET technology increases the mean execution time, the reduction of motion artifacts and the increase of high-quality images may represent a great advantage in clinical practice.

DualTrack technology improves optical coherence tomography angiography image quality

Bandello, Francesco;Querques, Giuseppe
2017-01-01

Abstract

BACKGROUND AND OBJECTIVE: To evaluate the effects of DualTrack Motion Correction Technology on the performance of AngioVue optical coherence tomography angiography (Optovue, Freemont, CA). PATIENTS AND METHODS: Fifty subjects underwent two consecutive examinations with AngioVue. The operator inactivated the eye-tracking (ET) technology before the second examination. Two operators measured execution time, excluded low-quality images, and counted the number of motion artifacts per image. RESULTS: The mean execution time was lower without ET in all the groups (P < .05), regardless of retinal diseases. Percentages of available images and low-quality images were 75.0% and 25.0%, respectively, with ET and 63.0% and 37.0%, respectively, without ET. Mean number of motion artifacts was significantly lower in images obtained using ET compared to images obtained without ET in all the groups (P < .0001), regardless of retinal diseases. CONCLUSION: Although ET technology increases the mean execution time, the reduction of motion artifacts and the increase of high-quality images may represent a great advantage in clinical practice.
2017
Inglese
Slack Incorporated
48
11
918
926
9
Pubblicato
https://www.healio.com/ophthalmology/journals/osli/2017-11-48-11/%7B3c37c73a-c9a0-48b9-8955-2e916ade0475%7D/dualtrack-technology-improves-optical-coherence-tomography-angiography-image-quality
Adult; Artifacts; Computed Tomography Angiography; Female; Healthy Volunteers; Hemodynamics; Humans; Male; Middle Aged; Retinal Diseases; Retinal Vessels; Tomography, Optical Coherence; Surgery; Ophthalmology
No
none
8
info:eu-repo/semantics/article
262
De Vitis, Luigi A.; Sacconi, Riccardo; Carnevali, Adriano; Centoducati, Teresa; Cavalleri, Michele; Querques, Lea; Bandello, Francesco; Querques, Gius...espandi
1 Contributo su Rivista::1.1 Articolo in rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.