Purpose The aim of this study was to compare the accuracy of different laboratory scanners using a calibrated coordinate measuring machine as reference. Methods A sand blasted titanium reference model (RM) was scanned with an industrial 3D scanner in order to obtain a reference digital model (dRM) that was saved in the standard tessellation format (.stl). RM was scanned ten times with each one of the tested scanners (GC Europe Aadva, Zfx Evolution, 3Shape D640, 3Shape D700, NobilMetal Sinergia, EGS DScan3, Open Technologies Concept Scan Top) and all the scans were exported in.stl format for the comparison. All files were imported in a dedicated software (Geomagic Qualify 2013). Accuracy was evaluated calculating trueness and precision. Results Trueness values (μm [95% confidence interval]) were: Aadva 7,7 [6,8–8,5]; Zfx Evolution 9,2 [8,6–9,8]; D640 18,1 [12,2–24,0]; D700 12,8 [12,4–13,3]; Sinergia 31,1 [26,3–35,9]; DScan3 15,6 [11,5–19,7]; Concept Scan Top 28,6 [25,6–31,6]. Differences between scanners were statistically significant (p <.0005). Precision values (μm [95% CI]) were: Aadva 4,0 [3,8–4,2]; Zfx Evolution 5,1 [4,4–5,9]; D640 12,7 [12,4–13,1]; D700 11,0 [10,7–11,3]; Sinergia 16,3 [15,0–17,5]; DScan3 9,5 [8,3–10,6]; Concept Scan Top 19,5 [19,1–19,8]. Differences between scanners were statistically significant (p <.0005). Conclusions The use a standardized scanning procedure fabricating a titanium reference model is useful to compare trueness and precision of different laboratory scanners; two laboratory scanners (Aadva, Zfx Evolution) were significantly better that other tested scanners.

Evaluation of the accuracy of extraoral laboratory scanners with a single-tooth abutment model: A 3D analysis / Mandelli, Federico; Gherlone, Enrico; Gastaldi, Giorgio; Ferrari, Marco. - In: JOURNAL OF PROSTHODONTIC RESEARCH. - ISSN 1883-1958. - 61:4(2017), pp. 363-370. [10.1016/j.jpor.2016.09.002]

Evaluation of the accuracy of extraoral laboratory scanners with a single-tooth abutment model: A 3D analysis

Gherlone, Enrico;Gastaldi, Giorgio;
2017-01-01

Abstract

Purpose The aim of this study was to compare the accuracy of different laboratory scanners using a calibrated coordinate measuring machine as reference. Methods A sand blasted titanium reference model (RM) was scanned with an industrial 3D scanner in order to obtain a reference digital model (dRM) that was saved in the standard tessellation format (.stl). RM was scanned ten times with each one of the tested scanners (GC Europe Aadva, Zfx Evolution, 3Shape D640, 3Shape D700, NobilMetal Sinergia, EGS DScan3, Open Technologies Concept Scan Top) and all the scans were exported in.stl format for the comparison. All files were imported in a dedicated software (Geomagic Qualify 2013). Accuracy was evaluated calculating trueness and precision. Results Trueness values (μm [95% confidence interval]) were: Aadva 7,7 [6,8–8,5]; Zfx Evolution 9,2 [8,6–9,8]; D640 18,1 [12,2–24,0]; D700 12,8 [12,4–13,3]; Sinergia 31,1 [26,3–35,9]; DScan3 15,6 [11,5–19,7]; Concept Scan Top 28,6 [25,6–31,6]. Differences between scanners were statistically significant (p <.0005). Precision values (μm [95% CI]) were: Aadva 4,0 [3,8–4,2]; Zfx Evolution 5,1 [4,4–5,9]; D640 12,7 [12,4–13,1]; D700 11,0 [10,7–11,3]; Sinergia 16,3 [15,0–17,5]; DScan3 9,5 [8,3–10,6]; Concept Scan Top 19,5 [19,1–19,8]. Differences between scanners were statistically significant (p <.0005). Conclusions The use a standardized scanning procedure fabricating a titanium reference model is useful to compare trueness and precision of different laboratory scanners; two laboratory scanners (Aadva, Zfx Evolution) were significantly better that other tested scanners.
2017
Extraoral digital impression; Extraoral scanning; Precision; Repeatability; Sensitivity and Specificity; Titanium; Dental Abutments; Dental Models; Imaging, Three-Dimensional; Tomography, X-Ray Computed; Oral Surgery; Dentistry (miscellaneous)3502 Dental Assisting
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/80287
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 59
  • ???jsp.display-item.citation.isi??? 56
social impact