Background: This studywas designed to confirmin a large population of unselected patients the promising results of Ultimaster (R) biodegradable polymer sirolimus-eluting stent (BP-SES) already shown in previous trial.Methods: ULISSE is an observational, multicenter, national registry evaluating all patients undergoing PCI with the Ultimaster (R) BP-SES. Incidence of 1-year TLF (cardiac death or target vessel MI or clinically indicated TLR) was the primary endpoint. Pre-specified subgroup analysis was performed for diabetic patients and for those with lesion longer than 25 mm, bifurcation and CTO lesions.Results: 1660 patients were enrolled in 9 Italian cardiology centers, 82% weremales, mean age of 68 +/- 10 years, and 29% were diabetics. Overall 2422 lesions were treated, 65% type B2/C lesions, 7% CTOs, 17% bifurcations and 38% long lesions. The incidence of 1-year TLF was 5%, with 3.2% of clinically indicated TLR. TLF occurred in 8% of the patientswith diabetes mellitus, and 7% in bifurcation, 6.7% in CTO and 6.2% in long lesions. Definite overall ST was 0.9%, and 1.2% in patients treated for type B2/C lesions. Multivariate logistic regression analysis identified stenting on unprotected LMT (OR = 4.80), stenting on ISR lesion (OR = 3.19) and need for rotational atherectomy (OR = 6.24) as the strongest independent predictors of TLF.Conclusions: The results of this national all-comers registry show that the Ultimaster (R) BP-SES real-world performance was comparable with that observed in the clinical trial, with low rate of primary endpoint and TLR. Long term follow-up will be necessary to prove the theoretical advantage of the BP-SES over time. (c) 2018 Elsevier B.V. All rights reserved.
One-year clinical outcome of biodegradable polymer sirolimus-eluting stent in all-comers population. Insight from the ULISSE registry (ULtimaster Italian multicenter all comerS Stent rEgistry) / Godino, Cosmo; Beneduce, Alessandro; Ferrante, Giuseppe; Ielasi, Alfonso; Pivato, Andrea Carlo; Chiarito, Mauro; Cappelletti, Alberto; Perfetti, Giulia; Magni, Valeria; Prati, Eugenio; Falcone, Stefania; Pierri, Adele; De Martini, Stefano; Montorfano, Matteo; Parisi, Rosario; Rutigliano, David; Locuratolo, Nicola; Anzuini, Angelo; Tespilli, Maurizio; Margonato, Alberto; Benassi, Alberto; Briguori, Carlo; Fabbiocchi, Franco; Reimers, Bernhard; Bartorelli, Antonio; Colombo, Antonio. - In: INTERNATIONAL JOURNAL OF CARDIOLOGY. - ISSN 0167-5273. - 260:(2018), pp. 36-41-41. [10.1016/j.ijcard.2018.02.014]
One-year clinical outcome of biodegradable polymer sirolimus-eluting stent in all-comers population. Insight from the ULISSE registry (ULtimaster Italian multicenter all comerS Stent rEgistry)
Montorfano, Matteo;Margonato, Alberto;Colombo, Antonio
2018-01-01
Abstract
Background: This studywas designed to confirmin a large population of unselected patients the promising results of Ultimaster (R) biodegradable polymer sirolimus-eluting stent (BP-SES) already shown in previous trial.Methods: ULISSE is an observational, multicenter, national registry evaluating all patients undergoing PCI with the Ultimaster (R) BP-SES. Incidence of 1-year TLF (cardiac death or target vessel MI or clinically indicated TLR) was the primary endpoint. Pre-specified subgroup analysis was performed for diabetic patients and for those with lesion longer than 25 mm, bifurcation and CTO lesions.Results: 1660 patients were enrolled in 9 Italian cardiology centers, 82% weremales, mean age of 68 +/- 10 years, and 29% were diabetics. Overall 2422 lesions were treated, 65% type B2/C lesions, 7% CTOs, 17% bifurcations and 38% long lesions. The incidence of 1-year TLF was 5%, with 3.2% of clinically indicated TLR. TLF occurred in 8% of the patientswith diabetes mellitus, and 7% in bifurcation, 6.7% in CTO and 6.2% in long lesions. Definite overall ST was 0.9%, and 1.2% in patients treated for type B2/C lesions. Multivariate logistic regression analysis identified stenting on unprotected LMT (OR = 4.80), stenting on ISR lesion (OR = 3.19) and need for rotational atherectomy (OR = 6.24) as the strongest independent predictors of TLF.Conclusions: The results of this national all-comers registry show that the Ultimaster (R) BP-SES real-world performance was comparable with that observed in the clinical trial, with low rate of primary endpoint and TLR. Long term follow-up will be necessary to prove the theoretical advantage of the BP-SES over time. (c) 2018 Elsevier B.V. All rights reserved.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.