Objective: The aim of this study is to evaluate the open transaxillary placement of the Impella 5.0 with a modified surgical technique. Methods: From January to July 2018, nine patients (eight males; mean age 60 years) underwent surgical transaxillary Impella 5.0 (Abiomed Inc., Danvers, MA) implantation. Patient and periprocedural data were recorded in a prospectively maintained institutional database. The primary endpoint was technical success. The secondary endpoints were: neurological complications (peripheral or central), bleeding, and wound infection, duration of Impella support, and device failure requiring device replacement. Results: Assisted technical success was 100%. The right axillary artery was used in 8/9 cases. Three patients (all on extracorporeal membrane oxygenation) suffered from access site bleeding which required surgical reintervention. One patient suffered from peripheral neurological dysfunction which recovered in 1 month and one patient had a local hematoma which was managed conservatively. The median length of treatment was 16 days (range 8-35). Five patients had myocardial recovery and the Impella could be explanted; the remaining were transitioned to a durable left ventricular assist device with an uneventful postoperative course. Hospital mortality was 33%. Conclusions: Open Impella 5.0 device implantation through the axillary artery is safe and effective; technical success was 100% and low rates of major complications are reported.

Surgical transaxillary placement of the Impella 5.0 ventricular assist device

Bertoglio, Luca;Chiesa, Roberto;Pappalardo, Federico
2019-01-01

Abstract

Objective: The aim of this study is to evaluate the open transaxillary placement of the Impella 5.0 with a modified surgical technique. Methods: From January to July 2018, nine patients (eight males; mean age 60 years) underwent surgical transaxillary Impella 5.0 (Abiomed Inc., Danvers, MA) implantation. Patient and periprocedural data were recorded in a prospectively maintained institutional database. The primary endpoint was technical success. The secondary endpoints were: neurological complications (peripheral or central), bleeding, and wound infection, duration of Impella support, and device failure requiring device replacement. Results: Assisted technical success was 100%. The right axillary artery was used in 8/9 cases. Three patients (all on extracorporeal membrane oxygenation) suffered from access site bleeding which required surgical reintervention. One patient suffered from peripheral neurological dysfunction which recovered in 1 month and one patient had a local hematoma which was managed conservatively. The median length of treatment was 16 days (range 8-35). Five patients had myocardial recovery and the Impella could be explanted; the remaining were transitioned to a durable left ventricular assist device with an uneventful postoperative course. Hospital mortality was 33%. Conclusions: Open Impella 5.0 device implantation through the axillary artery is safe and effective; technical success was 100% and low rates of major complications are reported.
2019
access; conduit; Impella; open; technique; transaxillary; Surgery; Pulmonary and Respiratory Medicine; Cardiology and Cardiovascular Medicine
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/85457
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 17
social impact