The aim of this study is to describe our 9-year experience in transcatheter aortic valve replacement (TAVR) using transthoracic echocardiography (TTE) as a routine intra-procedural imaging modality with trans-oesophageal echocardiography (TEE) as a backup.

Intra-procedural monitoring protocol using routine transthoracic echocardiography with backup trans-oesophageal probe in transcatheter aortic valve replacement: a single centre experience / Stella, S; Melillo, F; Capogrosso, C; Fisicaro, A; Ancona, F; Latib, A; Montorfano, M; Colombo, A; Alfieri, O; Castiglioni, A; Margonato, A; Agricola, E. - In: EUROPEAN HEART JOURNAL. CARDIOVASCULAR IMAGING. - ISSN 2047-2404. - (2019). [Epub ahead of print] [10.1093/ehjci/jez066]

Intra-procedural monitoring protocol using routine transthoracic echocardiography with backup trans-oesophageal probe in transcatheter aortic valve replacement: a single centre experience

Montorfano, M;Alfieri, O;Castiglioni, A;Margonato, A;Agricola, E
2019-01-01

Abstract

The aim of this study is to describe our 9-year experience in transcatheter aortic valve replacement (TAVR) using transthoracic echocardiography (TTE) as a routine intra-procedural imaging modality with trans-oesophageal echocardiography (TEE) as a backup.
2019
echocardiography; fluoroscopy; intra-procedural monitoring; transcatheter aortic valve implantation
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/94247
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 5
social impact