Laparoscopic ventral mesh rectopexy (LVR) is gaining wider acceptance as the preferred procedure to correct internal as well as external rectal prolapse associated with obstructed defaecation syndrome and/or faecal incontinence. Very few reports exist on the use of biologic mesh for LVR. The aim of our study was to report the complication and recurrence rate of our first 100 cases of LVR for symptomatic internal rectal prolapse and/or rectocele using a porcine dermal collagen mesh. Prospectively collected data on LVR for internal rectal prolapse were analysed. Surgical complications and functional results in terms of faecal incontinence (measured with the Faecal Incontinence Severity Index = FISI) and constipation (measured with the Wexner Constipation Score = WCS) at 3, 6 and 12 months were analysed. It was considered an improvement if FISI or WCS scores were reduced by at least 25 % and a cure if the FISI score decreased to < 10 and the WCS decreased to < 5. Between April 2009 and April 2013, 100 consecutive female patients (mean age 63 years, range 24-88 years) underwent LVR. All patients had internal rectal prolapse (grade III [n = 25] and grade IV [n = 75] according to the Oxford classification) and rectocele. Mean operative time was 85 +/- A 40 min. Conversion rate to open technique was 1 %. There was no post-operative mortality. Overall 16 patients (16 %) experienced 18 complications, including rectal perforation (n = 1), small bowel obstruction (n = 2), urinary tract infection (n = 8), subcutaneous emphysema (n = 3), wound haematoma (n = 2), long lasting sacral pain (n = 1) and incisional hernia (1). Median post-operative length of stay was 2 days. Ninety-eight out of 100 patients completed follow-up. At the end of follow-up, the mean FISI score improved from 8.4 (+/- 4.0 standard deviation (SD) p = 0.003) to 3.3 +/- 2.3 SD (p = 0.04). Incontinence improved in 37 out of 43 patients (86 %), and 31 patients (72 %) were cured. Similarly, the mean WCS score improved from 18.4 +/- 11.6 SD to 5.4 +/- 4.1 SD (p = 0.04). Constipation improved in 82 out of 89 patients (92 %), and 70 patients (79 %) were cured. No worsening of continence status, constipation or sexual function was observed. Fourteen patients (14 %) experienced persistence or recurrence of prolapse. LVR using biologic mesh is a safe and effective procedure for improving symptoms of obstructed defaecation and faecal incontinence in patients with internal rectal prolapse associated with rectocele.

Laparoscopic ventral rectopexy using biologic mesh for the treatment of obstructed defaecation syndrome and/or faecal incontinence in patients with internal rectal prolapse: a critical appraisal of the first 100 cases / Franceschilli, L; Varvaras, D; Capuano, I; Ciangola, Ci; Giorgi, F; Boehm, G; Gaspari, Al; Sileri, P. - In: TECHNIQUES IN COLOPROCTOLOGY. - ISSN 1123-6337. - 19:4(2015), pp. 209-219. [10.1007/s10151-014-1255-4]

Laparoscopic ventral rectopexy using biologic mesh for the treatment of obstructed defaecation syndrome and/or faecal incontinence in patients with internal rectal prolapse: a critical appraisal of the first 100 cases

Sileri P
2015-01-01

Abstract

Laparoscopic ventral mesh rectopexy (LVR) is gaining wider acceptance as the preferred procedure to correct internal as well as external rectal prolapse associated with obstructed defaecation syndrome and/or faecal incontinence. Very few reports exist on the use of biologic mesh for LVR. The aim of our study was to report the complication and recurrence rate of our first 100 cases of LVR for symptomatic internal rectal prolapse and/or rectocele using a porcine dermal collagen mesh. Prospectively collected data on LVR for internal rectal prolapse were analysed. Surgical complications and functional results in terms of faecal incontinence (measured with the Faecal Incontinence Severity Index = FISI) and constipation (measured with the Wexner Constipation Score = WCS) at 3, 6 and 12 months were analysed. It was considered an improvement if FISI or WCS scores were reduced by at least 25 % and a cure if the FISI score decreased to < 10 and the WCS decreased to < 5. Between April 2009 and April 2013, 100 consecutive female patients (mean age 63 years, range 24-88 years) underwent LVR. All patients had internal rectal prolapse (grade III [n = 25] and grade IV [n = 75] according to the Oxford classification) and rectocele. Mean operative time was 85 +/- A 40 min. Conversion rate to open technique was 1 %. There was no post-operative mortality. Overall 16 patients (16 %) experienced 18 complications, including rectal perforation (n = 1), small bowel obstruction (n = 2), urinary tract infection (n = 8), subcutaneous emphysema (n = 3), wound haematoma (n = 2), long lasting sacral pain (n = 1) and incisional hernia (1). Median post-operative length of stay was 2 days. Ninety-eight out of 100 patients completed follow-up. At the end of follow-up, the mean FISI score improved from 8.4 (+/- 4.0 standard deviation (SD) p = 0.003) to 3.3 +/- 2.3 SD (p = 0.04). Incontinence improved in 37 out of 43 patients (86 %), and 31 patients (72 %) were cured. Similarly, the mean WCS score improved from 18.4 +/- 11.6 SD to 5.4 +/- 4.1 SD (p = 0.04). Constipation improved in 82 out of 89 patients (92 %), and 70 patients (79 %) were cured. No worsening of continence status, constipation or sexual function was observed. Fourteen patients (14 %) experienced persistence or recurrence of prolapse. LVR using biologic mesh is a safe and effective procedure for improving symptoms of obstructed defaecation and faecal incontinence in patients with internal rectal prolapse associated with rectocele.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/96238
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 49
  • ???jsp.display-item.citation.isi??? 46
social impact