Purpose: Hysteresis is a viscoelastic property characterized by the difference in behavior under loading and unloading. The aim of the study was to determine corneal hysteresis using experimental means. Methods: Twenty-nine human corneas with 50-95 year age were subjected to cycles of pressure loading and unloading. Two pressure application rates were adopted to approximate static and dynamic loading conditions. Results: The behavior under both loading and unloading was found to stiffen with increased age. The unloading behavior appeared to be largely independent of the pressure level at which unloading started. The difference between the behavior patterns under loading and unloading was quantified and used as a measure of corneal hysteresis. The hysteresis area was significantly larger with faster loading and with decreased age. Conclusions: The trend for hysteresis to decrease with age is in agreement with previous clinical observations. Hysteresis was also found to increase with faster pressure application.

Experimental assessment of human corneal hysteresis / Elsheikh, A; Wang, Df; Rama, P; Campanelli, M; Garway-Heath, D. - In: CURRENT EYE RESEARCH. - ISSN 0271-3683. - 33:3(2008), pp. 205-213. [10.1080/02713680701882519]

Experimental assessment of human corneal hysteresis

Rama P;
2008-01-01

Abstract

Purpose: Hysteresis is a viscoelastic property characterized by the difference in behavior under loading and unloading. The aim of the study was to determine corneal hysteresis using experimental means. Methods: Twenty-nine human corneas with 50-95 year age were subjected to cycles of pressure loading and unloading. Two pressure application rates were adopted to approximate static and dynamic loading conditions. Results: The behavior under both loading and unloading was found to stiffen with increased age. The unloading behavior appeared to be largely independent of the pressure level at which unloading started. The difference between the behavior patterns under loading and unloading was quantified and used as a measure of corneal hysteresis. The hysteresis area was significantly larger with faster loading and with decreased age. Conclusions: The trend for hysteresis to decrease with age is in agreement with previous clinical observations. Hysteresis was also found to increase with faster pressure application.
2008
http://hdl.handle.net/20.500.11768/96991
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/96991
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 65
  • ???jsp.display-item.citation.isi??? 56
social impact